![SICK AFM60 S01 Operating Instructions Manual Download Page 20](http://html.mh-extra.com/html/sick/afm60-s01/afm60-s01_operating-instructions-manual_1264520020.webp)
Chapter
3
Operating Instructions
AFS60/AFM60 EtherNet/IP
20
Product description
ID
Access
Name
Description
Data type
Default value
100
64h
Get
Vendor
EADK version (EtherNet/IP
Adapter Developers Kit)
(e.g. V4.1.0)
UDINT
00040100h
101
65h
Get
Vendor
Firmware version in the
FPGA (e.g. 1.1.0)
UDINT
00010100h
102
66h
Get
Vendor
Supported ports of the
FPGA
9 = 2 ports
UDINT
00000009h
103
67h
Get
Vendor
Hardware version
UDINT
00000101h
Bit
Name
Description
Default value
0
Owned
0 = No connection to the master
1 = Connection to the master
established
0
1
–
Reserved
0
2
Configured
0 = Device with standard configuration
1 = No standard configuration
0
3
–
Reserved
0
4 … 7
Extended
Device
Status Field
Vendor specific status bits
See Tab. 10
8
Minor
Recoverable
Status
0 = No error
1 = Recoverable error (device not in
error status)
0
9
Minor
Unrecoverable
Status
0 = No error
1 = Recoverable error (device not in
error status)
0
10
Major
Recoverable
Status
0 = No serious error
1 = Recoverable serious error (device in
error status)
0
11
Major
Unrecoverable
Status
0 = No serious error
1 = Unrecoverable serious error (device
in error status)
0
12 … 15
–
Reserved
0000
Tab. 9: Bits of the instance
attribute “Status”
© SICK AG• Germany • All rights reserved
8018909/1EH9/2021-12-16
Subject to change without notice