Chapter
4
Operating Instructions
AFS60/AFM60 EtherNet/IP
42
Commissioning
Click on
Clear History
.
After a delay the encoder appears both in
Request History
and in
Relation List
with the IP
address entered. After one minute or four unsuccessful requests the default IP address
192.168.1.123 is set.
The Mod LED on the AFS60/AFM60 EtherNet/IP illuminates green continuously (the
encoder now has a valid IP address).
Checking the integration in EtherNet/IP via RSLinx Classic
With the aid of the tool
RSLinx Classic
you can again check whether the IP address set is
detected by the control system.
Start
RSLinx Classic
(as a rule on the Start menu on your PC/notebook in
Rockwell
Software
,
RSLinx
,
RSLinx Classic
).
Click on the
RSWho
button in the program.
Then open the path AB_ETHIP
G
1, Ethernet.
The encoder can be seen with its IP address.
Fig. 19: Integration of the IP
address in the BOOTP/DHCP
server
Green
Fig. 20: RSWho button in
RSLinx Classic
Fig. 21: Encoder on the path
AB_ETHIP
B
1 in RSLinx Classic
© SICK AG• Germany • All rights reserved
8018909/1EH9/2021-12-16
Subject to change without notice