Operating Instructions
Chapter
3
AFS60/AFM60 EtherNet/IP
31
Product description
ID
Ac-
cess
V/NV
4)
Name
Description
Data
type
Min.
Max.
(Default value)
43
2Bh
Get
NV
Physical
Resolution
Number of
Span
Physical number of
revolutions
Singleturn = 0001h
Multiturn = 1000h
UINT
(0001h)
or
(1000h)
44
2Ch
Get
V
Alarms
Bit field with flags for
alarms and errors (see
Tab. 26 on page 68)
WORD
–
45
2Dh
Get
NV
Supported
Alarms
Supported alarms and
errors
WORD
3003h
46
2Eh
Get
V
Alarm flag
0 = No alarm/error
1 = Alarm/error
BOOL
–
47
2Fh
Get
V
Warnings
Bit field with flags for
warnings (see Tab. 27
on page 69)
WORD
–
48
30h
Get
NV
Supported
Warnings
Supported warnings
WORD
67C3h
49
31h
Get
V
Warning
flag
0 = No warning
1 = Warning
BOOL
–
50
32h
Get
NV
Operating
Time
Saved operating time in
0.1h = 6 min
UDINT
0
51
33h
Get
NV
Offset
Value
Offset value is calcula-
ted on the initialization
of the preset function
DINT
00000000h
100
64h
Get
V
Tempera-
ture Value
Actual temperature with
±5° accuracy
–40 to +100 °C or
–40 to +212 °F
INT
F060h
2710h
101
65h
Set
NV
Tempera-
ture Value
Format
1200h = °C (Celsius)
1201h = °F
(Fahrenheit)
ENG
UINT
(1200h)
102
66h
Set
NV
Tempera-
ture Reso-
lution
Lowest resolution for
the temperature
(°C/100 or °F/100)
UDINT
(00000064h)
103
67h
Set
NV
Minimum
Tempera-
ture Set-
point
INT
F060h
–
(F060h =
–4,000)
104
68h
Set
NV
Maximum
Tempera-
ture Set-
point
Minimum/maximum
temperature. If the
temperature drops
below/exceeds this
value, the warning flag
(ID47) is set.
INT
–
2710h
(2710h =
+10,000)
or
(52D0h =
+21,200)
8018909/1EH9/2021-12-16
Subject to change without notice
© SICK AG• Germany • All rights reserved