AFS60/AFM60 EtherNet/IP
54
Commissioning
In the
Message Control
field select the variable TEMP_Message.
The MSG block must then be configured.
For this purpose click the button with the three dots.
The
Message Configuration
dialog box will open.
Configure the following parameters on the
Configuration
tab:
–
Service Type:
Get Attribute Single (see Tab. 16 on page 27)
–
Instance:
1 (as only one device is connected to the control system)
–
Class:
23(h) (Position Sensor Object, see Tab. 4 on page 17)
–
Attribute:
64(h) (Temperature Value, see Tab. 19 on page 28)
–
Destination:
TEMP_Value
Fig. 48: Allocation of the
variable TEMP_Message
to MSG
Fig. 49: Opening configu-
ration dialog box for the
MSG block
Fig. 50: Configuration dialog
box for the MSG block