AFS60 AFM60 EIP WEB operating instructions
26
4. Integration of AFx60 EtherNet / IP WEB encoder to
the RS logix project
Setup the RS logix project and integrate the AFx60 EtherNet / IP WEB encoder
as described in the AFS60 / AFM60 EtherNet / IP Operating Instruction,
part no.
8018909
, chapter “4.3 configuration”.
In this example the length of configuration assembly is set to 0 byte.
On the following pages the automatically generated module assemblies are displayed:
• Input assembly (104): I.Data [0 ... 13],
• Output assembly (106): O.data [0 ... 2] and
•
Configuration assembly (100): C.Data [0 ... 27].
© SICK AG• Germany • All rights reserved
8018909/1EH9/2021-12-16
Subject to change without notice