57
Technical Specifications
MiniPlex-2S
Supply voltage:
8 – 35 V
DC
, protected against reversed polarity.
Current consumption:
50 mA (100 mA max. with fully loaded talker ports)
Host interface:
RS-232, galvanically isolated
Inputs:
4 x NMEA 0183/RS-422, galvanically isolated. Input 4 can be set to
SeaTalk mode
Input resistance:
>800 Ohm
Input current:
1.2mA @ 2V
Outputs:
2 x NMEA 0183/RS-422
Max output current:
20mA @ >2V
Queue size:
1024 characters
Filter list size:
50 sentence types
Priority list size:
50 sentence types
Speed NMEA In 1-3:
4800 - 57600 Baud
Speed NMEA In 4/Out 1:
4800 - 57600 Baud
Speed NMEA Out 2:
4800 - 115200 Baud
Indicators:
Overflow and Data
Dimensions:
138 x 72 x 33 mm
Housing:
Flame retardant ABS.
MiniPlex-2USB
Supply voltage:
8 – 35 V
DC
, protected against reversed polarity.
Current consumption:
50 mA (100 mA max. with fully loaded talker ports)
Host interface:
USB, galvanically isolated
Inputs:
4 x NMEA 0183/RS-422, galvanically isolated. Input 4 can be set to
SeaTalk mode
Input resistance:
>800 Ohm
Input current:
1.2mA @ 2V
Outputs:
2 x NMEA 0183/RS-422
Max output current:
20mA @ >2V
Queue size:
1024 characters
Filter list size:
50 sentence types
Priority list size:
50 sentence types
Speed NMEA In 1-3:
4800 - 57600 Baud
Speed NMEA In 4/Out 1:
4800 - 57600 Baud
Speed NMEA Out 2:
4800 - 115200 Baud
Indicators:
Overflow and Data
Dimensions:
138 x 72 x 33 mm
Housing:
Flame retardant ABS.