4. Startup
Do not operate the switches with wet hands. Otherwise, it may cause an
electric shock.
Before running the servo motor, check the parameters. Any improper settings
may cause machines some unexpected operation.
The servo drive heat sink, regenerative resistor, servo motor, etc. may be hot
while power is on or for an interval after power off. Not to touch them mentioned
above to avoid burns.
4.1. Switching power on for the first time
When switching power on for the first time, follow the instructions below to make a startup.
4.1.1. Startup procedure
Check whether the servo drive and servo motor are wired correctly.
Check the ambient environment of the servo drive and servo motor.
Set the parameters properly, such as the regenerative option.
Decouple the servo motor from the machine and run at the speed as
low as possible, check whether the servo motor rotates correctly. Then
give commands to the servo drive and check whether the servo motor
rotates correctly.
After coupling the servo motor with the machine, check machine
motions are correct or not by sending operation commands from the
superior controller.
Make gain adjustment to optimize the machine motions.
Observe the motion of machine, check if any vibration occurred then to
suppress it.
Stop the servo motor.
Wiring check
Ambient check
Parameter setting
Idle test
Load test
Gain adjustment
Repetitive run
Stop
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...