136
Low-pass filter smooth time constant
Name
Name
Abbr.
Sign
Setting
range
Unit
Defa
ult
Control
mode
Speed low-pass filter smooth time constant [ms]
SFLT
PB18
0~1000
ms
0
S,T
A larger parameter value would soothe the speed command more obviously. However, the
response would slow down as well. If it is set as zero, this function is disabled.