101
No
Abbr.
Function description
Control
mode
Setting
range
Unit
PD19 DOP3 Alarm code output option
0 0 0 x
x
:
output option
0
:
DO function according to PD10 ~ PD14 setting
1: to show alarm codes while alarms occurred
x
CN1-41
CN1-42
CN1-45
0
DO function
DO function
DO function
1
Alarm code
CN1
code
Alarm name
41
42
45
0
0
0
AL 09
Communication abnormal
AL. 0A Communication time-out
AL. 0E IGBT overheat
AL. 0F Memory error
AL. 10 Overload 2
0
0
1
AL. 02 Low voltage
0
1
0
AL. 01 Over voltage
AL. 04 Regenerative alarm
0
1
1
AL. 03 Over current
1
0
0
AL. 05 Overload 1
1
0
1
AL. 06 Over speed
AL. 07 Pulse command abnormal
AL. 08 Position error excessive
1
1
0
AL. 0B Encoder error 1
AL. 0C Encoder error 2
1
1
1
AL. 11
Motor mismatch
Pt, Pr
S,T
0000h
~0001h
-
PD20 DOP4
Alarm reset triggered process
0 0 0 x
x
:
clear option
0
:
PWM signal off(If the motor is running, it would coast to
stop. If the motor is shaft-lock, it would become rotatable.
1:invalid
Pt, Pr
S,T
0000h
~001Fh
-
PD21
DI9
Digital input 9 option
The 12 DI input pins of CN1 are programmable. The default pin
functions are different corresponding to varied control modes.
Pt, Pr
S,T
0000h
~002Fh
-
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...