94
No
Abbr.
Function description
Control
mode
Setting
range
Unit
PC12
VCM
Output speed of maximum analog command
This value decides the output speed while the maximum
permissible voltage is applied.
applied voltage of speed command
output speed =
PC12
10
S
0
~30000
rpm
When torque mode is applied, this parameter would become
speed limit when the maximum permissible voltage applied.
applied voltage of torque command
Speed limit =
PC12
10
T
0
~30000
PC13
TLC
Torque generated of maximum analog command
To decides the maximum torque generated while the maximum
permissible voltage is applied.
applied voltage of torque command
Torque limit =
PC13
10
T
0
~2000
%
Torque generated of maximum analog command
When position or speed mode is applied, this parameter is
used to limit the output speed.
Pt, Pr
S
0
~2000
PC14
MOD
Analog monitor output
There are 2 channels of analog monitor provided for users to
check the required signals.
Refer to section 6.9.2 for details.
Pt, Pr
S,T
0000h
~0707h
-
PC15 SVZR
Speed analog zero voltage acknowledged range
Treat the applied voltage which is less than PC15 as zero
speed command.
S,T
0
~1000
mV
PC16
MBR
Electromagnetic brake
output delay time
The parameter PC16 could be used to decide the delay time of
the SON signal off to the MBR signal activated.
See section 6.6.3 for more details.
Pt, Pr
S,T
0
~1000
ms
PC17
ZSP
Zero speed acknowledged range
As motor feedback speed is less than the setting value of
PC17, the servo drive would treat it as zero speed and the ZSP
of DO would be outputted.
Pt, Pr
S,T
0
~10000
rpm
PC18 COP1
Stop option and
power
interruption restart option
The voltage level drop would cause drive to alarm and stop.
Auto-restart function could be applied by the setting of PC18.
0 0 y x
x
:
power
interruption restart option
0
:
invalid
1
:
valid
y
:
motor stop option
0
:
stops instantaneously
1
:
decelerates to stop
Pt, Pr
S,T
0000h
~0011h
-
Summary of Contents for SDE Series
Page 13: ...5 1 6 Function block diagram ...
Page 26: ...18 3 3 3 CN1 pin name list ...
Page 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Page 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Page 227: ...219 ...
Page 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Page 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...