Main code
Sub code
Description
Ref. Page
53
06
°
RADF and ADF timing sensor adjustment
Used to adjust the RADF timing sensor.
When this simulation is executed, the RADF timing sensor is adjusted and the adjustment value is
displayed.
07
°
RADF and ADF repulsion sensor adjustment
Used to adjust the RADF repulsion sensor.
When this simulation is executed, the RADF repulsion sensor is adjusted and the adjustment value is
displayed.
08
°
RADF and ADF empty sensor adjustment
Used to adjust the RADF empty sensor.
When this simulation is executed, the RADF empty sensor is adjusted and the adjustment value is
displayed.
(Trouble codes list)
Trouble status code
Subordinate code
Description
L4
01
Main motor lock detection
L5
03
No.4/5 mirror motor error detection
04
No.4/5 mirror motor MHPS error detection
05
Lens motor error detection
06
Lens motor LHPS error detection
L8
01
Power supply line frequency error detection
H2
—
Open thermistor (Test command 14 to reset)
H3
—
Heat roller high temperature detection (Test command 14 to reset)
H4
—
Heat roller low temperature detection (Test command 14 to reset)
U2
00
01
Memory. Counter sumcheck error detection (Test command 16 to reset)
U3
20
Mirror motor lock detection
21
Mirror motor MHPS error detection
U4
02
ADU alignment plate malfunction detected
04
ADU rear plate malfunction detected
U5
00
ADF communication trouble detected
01
A motor malfunction detected
02
B motor malfunction detected
03
Resist sensor malfunction detected
04
Eject sensor malfunction detected
U6
00
Desk communication trouble detected
01
Desk-1 cassette liftup motor trouble detected
02
Desk-2 cassette liftup motor trouble detected
03
Desk-3 cassette liftup motor trouble detected
08
Desk 24V line error detected
09
LCC motor overcurrent detected
10
Desk transport motor trouble detected
U7
00
Communication trouble between PC/Modem and the copier.
F1
00
Sorter communication trouble detected
01
Paper jog malfunction detected
02
Transport motor malfunction detected
04
Indexer lower limit detected
05
Indexer upper limit detected
06
Shift motor malfunction detected
F2
02
Toner motor malfunction detected
31
ID sensor level abnormality (less than 3V)
ID sensor photo conductor surface level abnormality (less than 2.25V)
32
DM sensor level abnormality (less than 3V)
DM sensor cannot sense.
When measuring the gain level (at 1.5 rotations of the drum)
DM sensor cannot sense.
When measuring the patch (at 1.5 rotations of the drum)
35
*
Adjustment impossible for GB (-32V
*
4 times)
Adjustment impossible for GB (+32V
*
7 times)
Preliminary adjustment impossible for GB (-200V to -88V)
F3
12
Main unit upper cassette liftup motor trouble detected
22
Main unit bottom cassette liftup motor trouble detected
EE
EL
Toner sensor indicates extreme overtoned condition
EU
Toner sensor indicates extreme undertoned condition
CC
—
Original size detect sensor level abnormality.
C2
00
THV leak trouble
Mark "
*
": The error display is given only when performing the simulation. (For the process control at warming-up,, the error display is not given.)
8 – 17
Summary of Contents for SF-2040
Page 27: ...9 Desk unit SF D23 11 12 16 17 13 18 10 9 8 7 6 2 5 4 3 1 23 21 22 19 20 14 15 4 10 ...
Page 63: ...5 5 C F 10 D 7 6 11 G E 8 9 H 12 6 2 ...
Page 65: ...3 B 3 E 13 C 4 5 6 7 8 F 14 D 10 11 9 6 4 ...
Page 67: ...2 1 3 A D 9 8 11 10 B 4 5 E 12 13 14 C 7 6 6 6 ...
Page 69: ...A a 1 1 D 4 4 B 1 b 1 1 E 5 5 7 6 8 9 8 5 C 2 3 3 F 5 11 12 6 8 ...
Page 71: ...1 2 3 3 4 5 A D 13 11 10 7 6 6 7 B E 14 8 12 9 C F 15 G 16 16 6 10 ...
Page 73: ...A a 1 D 11 10 10 9 8 B 4 2 3 E 13 12 12 C 5 7 6 7 6 12 ...
Page 75: ...C 4 F 9 9 9 10 9 5 6 D G 11 E 8 7 6 14 ...
Page 78: ...Volume PWB 8 9 10 10 6 17 ...
Page 80: ...C 5 F 11 P D F R 7 6 6 12 13 G 12 13 E 8 9 a 8 H 14 6 19 ...