Main code
Sub code
Description
Ref. Page
26
01
Option unit setup
•
Used to set up option unit.
1
When the test command is executed, the presently stored machine setup code is displayed with the
READY lamp turned on.
2
After the READY lamp has turned on, enter an appropriate setup code on the keypad and press the
PRINT switch. Then, the date is stored in the memory and the READY lamp turns off.
Code
Option
0
No option
+1
RADF
+2
ADU
+4
Desk
+10
Sorter
°
No need to set "+2 (ADU)". If the ADU is installed, "2" is automatically added.
°
Used to set the code that corresponds to an option unit.
(EX): To set the RADF and desk together with ADU, enter 1+2+4=7, or 1+4=5.
NOTES:
(1) Be sure to enter the code that corresponds to the installed option unit.
(2) If option setup is incorrect, a trouble code is displayed. See the trouble code chart.
03
Coin vendor setting
0: Cancel, 1: Setting
26
05
Counter mode setup
1
When the test command is executed, the code of the presently stored mode is displayed with the
READY lamp turned on.
2
After the READY lamp has turned on, enter an appropriate setup code on the keypad and press the
PRINT switch. Then, the code is stored in the memory and the READY lamp turns off.
Code
Total counter
Maintenance counter
0
Double count
Double count
1
Single count
Double count
2
Double count
Single count
3
Single count
Single count
06
Destination setup
Used to set the destination setting.
1
When the test command is executed, the presently stored model number and the destination code
are displayed (see table below) and the READY lamp turns on.
2
After the READY lamp has turned on, enter the model number and the destination code on the
keypad and press the PRINT switch to store the setting in the memory. The READY lamp then
turns off.
Code
Destination
AB/Inch
0
SEC (ES)
America
(Inch)
1
SEC
*
America
2
SECL
Canada
3
Other
4
Japan
(AB Japan)
5
Other
6
SEEG
German
(AB Export)
7
SUK
U.K.
8
SCA
Australia
9
Other
*
Energy star
07
Drum sensitivity setup
1
When the test command is executed, the number stored in the memory is recalled and the READY
lamp turns on.
2
A number 1 to 3 may be entered on the keypad while the RPL is active.
3
Press the PRINT switch after the number has been entered. With this, the READY lamp turns off
and the test command number is displayed.
°
Drum
Keypad entry
1
2
3
Sensitivity
1
2
3
8 – 10
Summary of Contents for SF-2040
Page 27: ...9 Desk unit SF D23 11 12 16 17 13 18 10 9 8 7 6 2 5 4 3 1 23 21 22 19 20 14 15 4 10 ...
Page 63: ...5 5 C F 10 D 7 6 11 G E 8 9 H 12 6 2 ...
Page 65: ...3 B 3 E 13 C 4 5 6 7 8 F 14 D 10 11 9 6 4 ...
Page 67: ...2 1 3 A D 9 8 11 10 B 4 5 E 12 13 14 C 7 6 6 6 ...
Page 69: ...A a 1 1 D 4 4 B 1 b 1 1 E 5 5 7 6 8 9 8 5 C 2 3 3 F 5 11 12 6 8 ...
Page 71: ...1 2 3 3 4 5 A D 13 11 10 7 6 6 7 B E 14 8 12 9 C F 15 G 16 16 6 10 ...
Page 73: ...A a 1 D 11 10 10 9 8 B 4 2 3 E 13 12 12 C 5 7 6 7 6 12 ...
Page 75: ...C 4 F 9 9 9 10 9 5 6 D G 11 E 8 7 6 14 ...
Page 78: ...Volume PWB 8 9 10 10 6 17 ...
Page 80: ...C 5 F 11 P D F R 7 6 6 12 13 G 12 13 E 8 9 a 8 H 14 6 19 ...