ADJUSTMENT
1 - 42
(c) Transfer belt speed adjustment/printer (Secondary scanning reproduction ratio)
Follow the procedure below to make a test print (PFP middle or lower cassette, A3/LD).
(1) [0] [5] + [PWR] ON
→
[1]
→
[E/S]
→
1
(Digital keys)
(2) Measure the distance “A” the distance between the 5th line and 25th line.
(3) In order to set the distance “A” to 200 mm ± 0.5 mm, use following steps to make the adjustment:
1
→
[488]
→
[START]
→
Set the value
→
[SET] or [INT]
→
[1]
→
[E/S]
→
1
*An increase in the value makes the reproduction scale (distance “A”) longer (in increments
of 0.25mm/step).
Notes:
1. Before making a test print, make sure that [100% A] is appeared on the top of the
message display after the [SET] icon or the [INT] key is pressed, and then make a test
print.
2. The effective adjustment value is within the range 1 to 255.
The default adjustment value is 128.
Print
movement
direction
A
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Summary of Contents for AR-650
Page 103: ...MAINTENANCE 2 6 Rear drive system 38 36 37 3 54 54 54 54 54 54 96 12 81 63 63 46 ...
Page 104: ...2 7 MAINTENANCE ADF front sectional view 100 104 109 105 106 102 108 99 101 103 107 98 ...
Page 122: ...SUPPLIES 3 10 13 CONNECT 15 CLOSE 2 1 14 CLOSE 1 2 16 TURN ON 17 PRESS 18 END ...
Page 169: ...Click Finish button then Virtual Modem installation is completed 5 5 ...
Page 179: ...To make the connection ONLINE mode click button before firmware downloading 5 15 ...
Page 194: ......
Page 195: ...MEMO ...
Page 196: ...MEMO ...
Page 197: ...MEMO ...
Page 198: ...MEMO ...
Page 199: ...MEMO ...