TROUBLE SHOOTING
4 - 2
[C26] [C29] Peak detection error exposure lamp disconnection detected
Does the exposure lamp light?
Yes
•
Check the connectors on the CCD and SLG boards for disconnection.
•
Check the shading plate on the rear of the original scale for dirt.
•
Check the CCD board for breaks and short-circuits.
•
Check the SLG board for breaks and short-circuits.
•
Replace the lens unit.
•
Replace the SLG board.
No
•
Check the lamp connectors for disconnection.
•
Check the thermostat to see if it has blown.
•
Check electrical continuity of the lamp.
•
Check SLG board connector pins J9-22, 23, 24, 25 and 26 for disconnection and the harness
for breaks and short-circuits.
•
Check the SLG board for breaks and short-circuits.
•
Replace the SLG board.
•
Replace the lamp regulator.