![Sharp AR-650 Service Handbook Download Page 156](http://html.mh-extra.com/html/sharp/ar-650/ar-650_service-handbook_367442156.webp)
TROUBLE SHOOTING
4 - 28
[Procedure 2]
Check the switch actuator of the front door. Are the switch and the sensor being working properly?
No
Connect the connector.
Yes
Check the front door switch. Is the switch normal?
No
Replace the switch.
Yes
Measure J11-12 voltage of the saddle switcher controller with the front door open. Is 5V being
supplied?
Yes
The sensor is broken, so replace it.
No
Replace the saddle stitcher controller board.
[Procedure 3]
Check the switch actuator of the exit door. Are the switch and the sensor being working properly?
No
Correct the mechanism.
Yes
Check the exit door switch. Is the switch normal?
No
Replace the switch.
Yes
Measure J11-9 voltage access of the saddle stitcher with the exit door is open. Is it 5V ?
Yes
the sensor is broken, so replace it.
No
Replace the saddle stitcher controller board.