8
Operation
MOVIFIT® SC operating displays
114
Operating Instructions – MOVIFIT
®
SC
8.1.5
States of the "RUN PS" LED (motor starter status LED)
The following figure shows the "RUN PS" LED (shown unlit). In the sample figure, the
PROFIBUS versions are shown in the "Technology" or "System" function level:
61126AXX
Unit status LED
LED
color
LED status
Operating status
MOVIFIT
®
motor starter power section
–
Off
No 24 V electronics power supply
Red
Steady light
24 V electronics power supply available:
•
Damages on motor starter PCB
Yellow
Steady light
Normal operation "No enable":
•
Motor starter ready for operation (24 V electronics power supply
and mains voltage present)
•
Motor starter power section not enabled
Green
Steady light
Normal operation "enable" for single-motor operation:
•
Motor starter ready for operation (24 V electronics power supply
and mains voltage present)
•
Motor enabled
Normal operation "enable" for dual-motor operation:
•
Motor starter ready for operation (24 V electronics power supply
and mains voltage present)
•
Both drives enabled
Green
1 x flash, break
Normal operation "enable" for dual-motor operation:
•
Motor starter ready for operation (24 V electronics power supply
and mains voltage present)
•
Drive 1 enabled
Green
2 x flash, pause
Normal operation "enable" for dual-motor operation:
•
Motor starter ready for operation (24 V electronics power supply
and mains voltage present)
•
Drive 2 enabled
Yellow
Steady flashing
24 V electronics power supply for motor starter power section present:
•
No mains voltage
•
Motor starter power section not ready
•
No fault
Yellow
Steady fast flashing
Operating state "Release brake of drive 1 and/or drive 2 without drive
enable"
Green/
Yellow
Flashing evenly with
alternating colors
Motor starter power section ready,
communication timeout with cyclic data transfer
Green
Steady fast flashing
Operating at the current limit
Red
Flashing evenly,
slowly
Internal CPU error, EEPROM error, output open, watchdog
Red
3 x flash, pause
Error 1 (Overcurrent in the motor)
Error 11 (Overtemperature in the output stage)
Error 44 (Ixt utilization)
DI03
DI01DI02
DI00
DI04DI05DI06DI07
DI08DI09DI10DI1
1
DI12/DO00
DI13/DO01
DI14/DO02
DI15/Do03SYS-FBUS-F
24V
-C
24V
-S
RUN
RUN PS
MOVIFIT
®
0
0
I