Electrical Installation
ABOX with terminals and cable glands "MTA...-S02.-...-00"
Operating Instructions – MOVIFIT
®
SC
45
61101AXX
SBus terminal CAN
No.
Name
Function
X35
1)
1
CAN_GND
0V reference potential for SBus (CAN)
2
CAN_H
SBus CAN_H – incoming
3
CAN_L
SBus CAN_L – incoming
4
+24V_C_PS
+24V supply – continuous voltage for peripheral devices
5
0V24_C
0V24 reference potential – continuous voltage for peripheral devices
(jumpered with X20/3)
11
CAN_GND
0V reference potential for SBus (CAN)
12
CAN_H
SBus CAN_H – outgoing
13
CAN_L
SBus CAN_L – outgoing
14
+24V_C_PS
+24V supply – continuous voltage for peripheral devices
15
0V24_C
0V24 reference potential – continuous voltage for peripheral devices
(jumpered with X20/3)
1) Terminals X35 can only be used with function level "Technology" or "System".
X29
1 2 3 4 5 6 7 8
6
X25
11 12 13 14 15 16 17 18
1 2 3 4 5 6 7 8
21 22 23 24 25 26 27 28
31 32 33 34 35 36 37 38
X20
X91
1 2 3 4
X1
X81
X8
X9
2
1
3
4
5
6
7
2
1
3
4
4
3
2
1
7
6
5
1
2 3 4
1
2
3 4
11 12 13 14
5 6
11 12 13 14 15 16
X45
11 12 13 14
21 22 23 24
31 32 33 34
1 2 3 4
15
25
35
5
S3
X50
1112 13 1415
1 2 3 4 5
X35
Diagnostic (RJ10 socket)
No.
Name
Function
X50
1
+5V
5 V supply
2
RS+
RS-485 diagnostic interface
3
RS–
RS-485 diagnostic interface
4
0V5
0 V reference potential for RS-485
1
2 3 4
Summary of Contents for MOVIFIT SC series