8
Operation
MOVIFIT® SC operating displays
108
Operating Instructions – MOVIFIT
®
SC
States of the
"BF" LED
States of the
"SF" LED
RUN
BF
SF
Function
level
Meaning
Troubleshooting
C
T
S
Green
Off
x
• •
MOVIFIT
®
is currently
exchanging data with
the PROFINET master
(data exchange)
–
Green
Flashing
green,
flashing
green/red
x
• •
The flashing function in the
PROFINET master configura-
tion is activated to visually
localize the stations.
–
Green
Red
x
• •
•
Connection to the
PROFINET master has
failed.
•
MOVIFIT
®
does not detect
baud rate.
•
Bus interruption
•
PROFINET master not in
operation.
•
Check the PROFINET
connection of the
MOVIFIT
®
•
Check the PROFINET
master.
•
Check all cables in your
PROFINET mains.
X
•
Any state
Valid for selected function level:
C = Function level "Classic"
T = Function level "Technology"
S = Function level "System"
RUN
BF
SF
Function
level
Meaning
Troubleshooting
C
T
S
x
x
Off
• •
•
Normal operating state
•
MOVIFIT
®
is exchanging
data with the connected
drive systems (MOVIMOT
®
integrated FC/SC).
–
x
x
Red
•
MOVIFIT
®
FC/SC cannot
exchange data with the inte-
grated FC/SC.
Check the DC 24 V voltage
supply and wiring of the
FC/SC.
x
x
Flashing
red
•
No PLC application program
loaded.
Load an application program
and, if necessary, restart the
integrated PLC.
x
x
Flashing
yellow
•
PLC application program
stopped.
Check the application
program using MOVITOOLS
®
MotionStudio and, if neces-
sary, restart the integrated
PLC.
X
•
Any state
Valid for selected function level:
C = Function level "Classic"
T = Function level "Technology"
S = Function level "System"
0
0
I