6
Electrical Installation
HanModular® ABOX "MTA...-H12.-...-00" and "MTA...-H22.-...-00"
Operating Instructions – MOVIFIT
®
SC
71
6.5.6
Assignment of M12 plug connectors X21 to X28 for connecting I/Os
Function level
"Classic" with
PROFIBUS or
DeviceNet
The following figure depicts the M12 plug connector (standard coding, female) for
connecting I/Os:
60564AXX
Assignment of M12 plug connectors X21 to X28 for connecting I/Os
No.
Pin
Name
Function
X21
1
V024-I
+24V sensor supply group I, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI00
Binary input DI00 (switching signal)
5
FE
Functional ground
X22
1
V024-I
+24V sensor supply group I, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI01
Binary input DI01 (switching signal)
5
FE
Functional ground
X23
1
V024-I
+24V sensor supply group I, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI02
Binary input DI02 (switching signal)
5
FE
Functional ground
X24
1
V024-II
+24V sensor supply group II, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI03
Binary input DI03 (switching signal)
5
FE
Functional ground
X25
1
V024-II
+24V sensor supply group II, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI04
Binary input DI04 (switching signal)
5
FE
Functional ground
X26
1
V024-II
+24V sensor supply group II, from +24V-C
2
res.
Reserved
3
0V24_C
0V24 reference potential for sensors
4
DI05
Binary input DI05 (switching signal)
5
FE
Functional ground
X27
1
V024-IV
+24V sensor supply group IV, from +24V-S
2
res.
Reserved
3
0V24_S
0V24 reference potential for actuators or sensors group IV
4
DI06/DO00
Binary input DI060 or binary output DO00 (switching signal)
5
FE
Functional ground
1
2
5
3
4