10
Technical Data
Hybrid cable "Cable type A"
Operating Instructions – MOVIFIT
®
SC
127
10.8 Hybrid cable "Cable type A"
Mechanical
design
• SEW works standard W3251 (817 953 0)
• Supply cores:
7 x 1.5 mm
2
• Control core pair:
2 x 0.75 mm
2
• Insulation:
TPE-U (polyurethane)
• Conductor: Bare E-Cu strand, extra fine wires with individual wire
Â
0.1 mm
• Shield:
Tinned E-Cu wire
• Overall diameter: 13.2 ... 15.9 mm
• Color of outer cable sheath: Black
Electrical
properties
• Conductor resistance for 1.5 mm
2
(at 20°C):
max. 13
Ê
/km
• Conductor resistance for 0.75 mm
2
(at 20°C):
max. 26
Ê
/km
• Operating voltage for 1.5 mm
2
core:
max. 750 V (
600 V)
• Operating voltage for 0.75 mm
2
core:
max. 350 V (
600 V)
• Insulation resistance at 20°C:
min. 20 M
Ê
x km
55292AXX
[1] Overall shield
[2] Shield
[1]
[2]
A
GNYE
BK U1
RD13
WH14
BK V1
BK W1
BU 15
BK1 BK2
P
i
f
kVA
Hz
n