Startup
Startup MOVIFIT® motor starter
100
Operating Instructions – MOVIFIT
®
SC
7.4
Startup MOVIFIT
®
motor starter
7.4.1
Startup mode
You can use one of the following startup modes to start the MOVIFIT
®
motor starter:
• MOVIFIT
®
SC can be put into operation quickly and easily in "
Easy
"
mode using DIP
switch S10 (
Æ
page 13).
• To operate the unit in "
Expert
"
mode, set DIP switch S10/1 to ON. This mode
includes additional parameters. The parameters can be adjusted to suit the applica-
tion using the "MOVITOOLS
®
MotionStudio" software tool (function levels "Classic"
and "Technology").
• Once you have activated "Expert" mode, the position of the DIP switches S10/2 to
S10/5 remains in effect until one of the parameters assigned to the DIP switch setting
is changed or the factory settings are activated.
• A unit DIP switch that is changed after the "Expert" mode has been activated will no
longer be evaluated.
Unit behavior
during transition
from "Easy"
mode to
"Expert" mode
If "Expert" mode is activated, all the parameters that have a factory setting and that
cannot be set using DIP switch S10, are set initially to their factory setting value.
For parameters that can be set using DIP switch S10, the DIP switch setting remains in
effect until the parameter is changed:
• Starter operating mode
• Rated supply voltage
• Rated brake voltage drive 1
• Rated brake voltage drive 2
Unit behavior
during transition
from "Expert"
mode to
"Easy" mode
If Expert mode is deactivated, all parameters are set to factory settings.
For the following parameters, which can be set using DIP switch S10, the DIP switch
setting is in effect:
• Starter operating mode
• Rated supply voltage
• Rated brake voltage drive 1
• Rated brake voltage drive 2
NOTES
Important: When you are using the "System" function level (MOVIVISION
®
), you must
activate "Expert" mode (switch S10/1 = ON).