6
Electrical Installation
ABOX with terminals and cable glands "MTA...-S02.-...-00"
Operating Instructions – MOVIFIT
®
SC
39
6.3.2
Fieldbus/option-independent terminal assignment
DANGER
The maintenance switch only disconnects the integrated motor circuit breaker from the
mains. Voltage is still present on the terminals of the MOVIFIT
®
unit.
Severe or fatal injuries from electric shock.
• Switch off the power to the MOVIFIT
®
using a suitable external disconnecting
device, and wait at least 1 minute before opening the wiring space.
61096AXX
The terminal diagrams depicted in this section differ depending on the fieldbus system
used. The area dependent on the fieldbus is therefore represented as hatched and is
described in the following sections.
X29
1 2 3 4 5 6 7 8
6
X20
1
2 3 4 5 6
11 12 13 14 15 16
5
6
7
2
1
1 2 3 4
3
4
5
6
7
2
1
3
4
X91
X81
X8
X9
1
4
2 3
X45
X25
11 12 13 14
11 12 13 14 15 16 17 18
21 22 23 24
31 32 33 34
1
1 2 3 4
2 3 4 5 6 7 8
21 22 23 24 25 26 27 28
31 32 33 34 35 36 37 38
15
25
35
5
S3
X50
1112 13 1415
1 2 3 4 5
X35
X1
1
2
3 4
11 12 13 14
Mains terminal (power bus)
No.
Name
Function
X1
1
PE
Mains connection PE (IN)
2
L1
Mains connection phase L1 (IN)
3
L2
Mains connection phase L2 (IN)
4
L3
Mains connection phase L3 (IN)
11
PE
Mains connection PE (OUT)
12
L1
Mains connection phase L1 (OUT)
13
L2
Mains connection phase L2 (OUT)
14
L3
Mains connection phase L3 (OUT)