7
Startup
Startup MOVIFIT®
Operating Instructions – MOVIFIT
®
SC
97
4. To start up the MOVIFIT
®
motor starter, see the section "Startup MOVIFIT
®
motor
starter" on page 100.
5. Mount MOVIFIT
®
EBOX on the ABOX and connect.
6. Switch on supply voltage(s) 24V-C and 24V-S. The associated control LEDs should
now light up green.
Bus termination
The bus terminating resistors are already installed in the MOVIFIT
®
ABOX (only for
ABOX with terminals and cable glands "MTA...-S02.-...-00") and can be activated using
the S1 switch (
Æ
page 13 and following). See the following table:
The following table shows the operating principle of the bus termination switch:
Bus termination ON = on
Bus termination OFF = off
(factory setting)
Bus termination switch S1
Bus termination ON = on
Bus termination OFF = off
57271AEN
57272AEN
ON
S1
ON
S1
ON
OFF
Bus
termination
Incoming
cable
Outgoing
cable
Switch
ON
OFF
Bus
termination
Incoming
cable
Outgoing
cable
Switch
NOTE
When using Hybrid ABOX "MTA...-S12.-...-00" or "MTA...-S22.-...-00" or HanModular
®
ABOX "MTA...-H12.-...-00" or "MTA...-H22.-...-00" please note:
• In contrast to the version with terminals, these connection boxes require a plug-in
bus terminator (M12) at the last station instead of the outgoing bus connection.