7
Startup
Startup MOVIFIT® motor starter
102
Operating Instructions – MOVIFIT
®
SC
DIP switch S10/2
Operating mode
• DIP switch S10/2 = OFF: Single-motor operation
• DIP switch S10/2 = ON: Dual-motor operation
DIP switch S10/3
Rated supply voltage
• DIP switch S10/3 = OFF: Selects rated mains voltage 400 V
Choose this setting when the mains supply a voltage of 3 x AC 380 V, 3 x AC 400 V
or 3 x AC 415 V.
• DIP switch S10/3 = ON: Selects rated mains voltage 500 V
Choose this setting when the mains supply a voltage of 3 x AC 460 V, 3 x AC 480 V
or 3 x AC 500 V.
DIP switch S10/4 /
S10/5
Selecting the rated brake voltage for SEW three-wire brakes
If you use motors with SEW three-wire brakes, the rated brake voltage must be selected
via DIP switches S10/4 and S10/5 in accordance with the following table.
STOP!
Important: For operation with one motor, use X8 and X81 terminals or the X8 plug
connector.
Do not connect the X9 and X91 terminals or the X9 plug connector in this operating
mode.
Setting options for DIP switches S10/4 and S10/5
DIP switch S10/4
DIP switch S10/5
Rated brake voltage
drive 1 and drive 2
0
0
400 V
1
1
500 V
1
0
Reserved
0
1
Reserved
STOP!
The rated brake voltage must match the rated supply voltage.
0
0
I