61
GENESIS 5000 MSE
GENESIS 5000 MSE
Power supply voltage U1 (50/60Hz)
3x400Vac ±15%
3x400Vac / 3x230Vac ±15%
Zmax (@PCC)
49m
Ω
*
49m
Ω
*
Slow blow line fuse
30A
30A / 63A
Communication bus
DIGITAL
DIGITAL
MMA maximum input power (kVA)
23.6 kVA
23.6 kVA / 24.5 kVA
MMA maximum input power (kW)
22.5 kW
22.5 kW / 23.3 kW
TIG maximum input power (kVA)
18.2 kVA
18.2 kVA / 18.9 kVA
TIG maximum input power (kW)
17.4 kW
17.4 kW / 18.0 kW
MIG/MAG maximum input power (kVA)
22.9 kVA
22.9 kVA / 23.9 kVA
MIG/MAG maximum input power (kW)
21.9 kW
21.9 kW / 22.7 kW
Power factor PF
0.95
0.95
Efficiency (
μ
)
88%
88% / 87%
Cos
ϕ
0.99
0.99
Max. input current I1max
33A
33A / 61.5A
Effective current I1eff
23.9A
23.9A / 38.9A
MMA duty factor (40°C)
(x=40%)
-
- / 500A
(x=50%)
500A
500A / -
(x=60%)
470A
470A / 450A
(x=100%)
420A
420A / 400A
MMA duty factor (25°C)
(x=80%)
500A
500A / -
(x=100%)
470A
470A / -
TIG duty factor (40°C)
(x=50%)
500A
500A / 500A
(x=60%)
470A
470A / 470A
(x=100%)
420A
420A / 420A
TIG duty factor (25°C)
(x=80%)
500A
500A / -
(x=100%)
470A
470A / -
MIG/MAG duty factor (40°C)
(x=40%)
-
- / 500A
(x=50%)
500A
500A / -
(x=60%)
470A
470A / 450A
(x=100%)
420A
420A / 400A
MIG/MAG duty factor (25°C)
(x=80%)
500A
500A / -
(x=100%)
470A
470A / -
Adjustment range I2
3-500A
3-500A
Open circuit voltage Uo
73Vdc
73Vdc
IP Protection rating
IP23S
IP23S
Insulation class
H
H
Dimensions (lxdxh)
690x290x510 mm
690x290x510 mm
Weight
37 kg.
38.5 kg.
Manufacturing Standards
EN 60974-1 / EN 60974-10
EN 60974-1 / EN 60974-10
Power supply cable
4x4 mm2
4x4 mm2
Length of power supply cable
5 m
5 m
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment complies with EN/IEC 61000-3-12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
Summary of Contents for Genesis 4000 MSE
Page 32: ...32...
Page 62: ...62...
Page 212: ...212...
Page 242: ...242...
Page 272: ...272...
Page 302: ...302...
Page 332: ...332...
Page 336: ...336 1 3 1 4 11 35 1 5...
Page 338: ...1 8 IP S IP23S 12 5 mm 60 2 2 1 2 2 10 2 3 400V 230V V 230 400V 338...
Page 339: ...339 15 15 2 1 5 2 4 MMA 3 4 1 2 WF ARC AIR 5 6 7 ARC AIR 8 9 TIG 10 11 TIG 12 13 14 15...
Page 341: ...341 8 9 64 3 3 3 4 LCD 1 2 3 1 m min 22 m min Default 1 0 m min 4 5 3 5 MMA TIG DC MIG MAG...
Page 354: ...5 6 Reset 354...
Page 355: ...355 encoder...
Page 356: ...356...
Page 357: ...357 7 7 1 MMA Hot Start Arc Force antisticking 7 2 TIG TIG Tungsten lnert Gas 3370 C H F lift...
Page 359: ...359 7 3 MIG MAG MIG SHORT ARC 1a SHORT a SPRAY ARC b SPRAY ARC 1b 2 3 2 3 1a 1b...
Page 366: ...366 GENESIS 4000 MSE 3x230 400V...
Page 367: ...367 GENESIS 4000 MSE LCD 3 5 LCD 4 7 3x400V...
Page 368: ...368 GENESIS 4000 MSE LCD 3 5 LCD 4 7 3x230 400V...
Page 369: ...369 GENESIS 5000 MSE 3x400V...
Page 370: ...370 GENESIS 5000 MSE LCD 3 5 LCD 4 7 3x400V...
Page 372: ...372 GENESIS 4000 MSE LCD 3 5 LCD 4 7 3x400V GENESIS 4000 MSE LCD 3 5 LCD 4 7 3x230 400V...
Page 373: ...373 GENESIS 5000 MSE 3x400V GENESIS 5000 MSE LCD 3 5 LCD 4 7 3x400V...