8.3.
Charging the battery
Highly discharged or sulphated batteries (formation of whitish lead sulphate deposit on the plates, which becomes hard) can no longer
regenerate or be charged in a generating set.
A discharged battery should be recharged immediately, or else it will suffer irreparable damage.
IMPORTANT
Battery charge
Example of charge:
- 12V 60 Ah battery = 6 A charging current;
- Charge status: 50% (acid density 1.19 and voltage when idle 12.30V);
- The battery is short 30 Ah, and this must be recharged.
- Charge factor: 1.2;
- 30 Ah x 1.2 = 36 Ah to be charged;
- Charging current: 6A, approximately 6 hours charging required; the charging
current must always be 1/10
th
of the nominal capacity of the battery.
Recharging is complete when the battery voltage and the acid density stop increasing.
The power of the charger must be suitable for the battery to be charged and the charging time available.
Note: if several batteries connected together are being recharged, the following points must be checked:
-
Are the batteries connected in series?
-
Is the voltage chosen exact? 1 battery x 12 V, 3 x 36V batteries.
-
Adjust the charge current to the lowest battery.
-
The power difference between the batteries must be as low as possible.
8.4.
Cleaning the battery
Keep the batteries clean and dry. The presence of impurities and rust on the battery and
terminals may cause the current jumps, voltage drops and the battery to discharge, particularly
in humid weather.
1. Clean any signs of oxidation on the battery terminals and the cable terminals using a brass
brush.
2. Fully tighten the cable terminals and lubricate them with grease for battery terminals or
vaseline. A terminal which is not secured correctly may cause sparks and therefore lead to
an explosion.
86/242
Summary of Contents for R33C3
Page 2: ......
Page 94: ...92 242 ...
Page 95: ...10 Appendix 10 1 Appendix A Engine user and maintenance manual 93 242 ...
Page 96: ...94 242 ...
Page 98: ...96 242 ...
Page 115: ...113 242 ...
Page 135: ...133 242 ...
Page 145: ...143 242 ...
Page 179: ...177 242 ...
Page 191: ...July 2009 Pub No 99610 29120 OPERATION MAINTENANCE MANUAL 189 242 ...
Page 192: ...Printed in Japan Pub No 99610 29120 190 242 ...
Page 193: ...10 2 Appendix B Alternator user and maintenance manual 191 242 ...
Page 194: ...192 242 ...
Page 196: ...194 242 ...
Page 227: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 225 242 ...
Page 242: ...14 LEROY SOMER 2010 11 f Installation and maintenance R438 NOTES 3971 en 240 242 ...
Page 243: ...LEROY SOMER 15 2010 11 f Installation and maintenance R438 NOTES 3971 en 241 242 ...