Pop-up error messages that display for invalid settings are listed in Table 4. Use
this information to help you correct frequency-related receiver setup errors. The
pages that follow contain detailed setup information for each Receiver Setup menu
option.
Table 4. Pop-up error messages
Displayed Messages
Local Oscillator frequency #2 is not valid for Ku-Band
Local Oscillator frequency #2 is less than Local Oscillator Frequency #1
Downlink frequency entered is out of range
Downlink frequency calculated from L-Band is out of range
L-Band frequency calculated from Downlink is out of range
To set the Frequency Mode
Step 1.
Move to
Freq Mode
and press SELECT to display available settings (L-Band/1,
L-Band/2 or Downlink). The default setting is L-Band/1.
Step 2.
When the desired setting is displayed on-screen, move to Exit and press
SELECT, or press 1 and then press SELECT to change the current setting.
A pop-up menu displays Save options.
Step 3.
Press 1 to save the new setting (YES), or follow the on-screen instructions, as
required.
Available options:
Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Repeat this action to change to another Frequency Mode. A valid Frequency Mode
is always required (i.e., for setting the L-Band or Downlink frequency).
To set the operating Frequency
Step 1.
Move to
Frequency
and press SELECT to replace the current setting.
Step 2.
Enter a valid frequency and then press SELECT. You can also press the
Ï
/
Ð
arrow buttons to display available settings (frequencies are displayed from
950 MHz through 2150 MHz [L-Band] and from 0 GHz through 15 GHz
[Downlink] in 250 kHz steps). The default setting is 950 MHz.
Step 3.
When the desired setting is displayed on-screen, move to Exit and press
SELECT, or press 1 and then press SELECT to change the current setting.
A pop-up menu displays Save options.
Step 4.
Press 1 to save the new setting (YES), or follow the on-screen instructions, as
required.
Available options:
Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Repeat this action to change to another frequency. A valid operating Frequency is
always required (i.e., for setting the L-Band or Downlink frequency).
To set the Local Oscillator #1 frequency
Step 1.
Move to
LO Freq #1
and press SELECT to replace the current setting.
Step 2.
Enter a valid frequency and then press SELECT. You can also press the
Ï
/
Ð
arrow buttons to display available settings (frequencies are displayed from 0
GHz through 15 GHz in 1 MHz steps). The default setting is 9.750 GHz.
Step 3.
When the desired setting is displayed on-screen, move to Exit and press
SELECT, or press 1 and then press SELECT to change the current setting.
A pop-up menu displays Save options.
Step 4.
Press 1 to save the new setting (YES), or follow the on-screen instructions, as
required.
Available options:
Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Repeat this action to change to another frequency. A Local Oscillator #1 frequency
setting is required only if Downlink or L-Band/1 Frequency Mode are set (N/A
1
displayed if Frequency Mode set to L-Band/2).
To set the Local Oscillator #2 frequency
Step 1.
Move to
LO Freq #2
and press SELECT to replace the current setting.