4XLFN6HWXSLQVWUXFWLRQV
Follow these quick setup instructions to find a signal using the BSR built-in signal
search function.
Step 1. Display the BSR MAIN MENU
by pressing MENU.
Step 2. Display the RECEIVER STATUS menu
by pressing 2 and then SELECT, or
move to Receiver Status and press SELECT.
Step 3. Display the RECEIVER SETUP menu
by pressing 3 and then SELECT, or move
to Receiver Setup and press SELECT.
Step 4. Enter the Local Oscillator #1 Frequency
(in GHz) based on C or Ku-Band
LNB/F operation and press SELECT (e.g., 10750 for Ku-Band, and 5150 for C-
Band).
Step 5. Enter the Symbol Rate
(in MS/s)
and press SELECT.
Step 6. Display the correct FEC Rate
and press SELECT.
Step 7. Activate the signal search to Find the signal
by moving to Find
and
pressing SELECT (set to ON).
The
Lock, Sig
Signal State is displayed when a signal is found.
Step 8. Save the settings:
(after signal found)
(a)
Move to Exit and press SELECT (or press 1 and then SELECT) to display the
Save pop-up menu.
(b)
Press 1 to save the new configuration (YES).
When the signal is found, the Find option is automatically set to OFF. You can also
terminate the search manually by setting the Find option to OFF. Repeat this action
to search for another signal. If no Remote Control is available, you can perform the
these functions using the following front panel buttons.
Save:
Press and hold down both the
Í
and
Î
arrow buttons simultaneously (5) to
save the new configuration (YES)
Discard:
Press and hold down both the
Ï
and
Ð
arrow buttons simultaneously (4)
to discard all changes (NO)
Cancel:
Press SELECT (3) to cancel the operation (CANCEL)
«$ERXWIDFWRU\GHIDXOWVHWWLQJV
Factory default settings can be modified at any time. A Factory Reset option is also
available for replacing the current settings with the factory defaults (see Table A).
Table A. Factory default settings
Option
Menu
Default setting
1.
Frequency Mode
Receiver Setup
L-Band/1
2.
Frequency
Receiver Setup
950 MHz
3.
Local Oscillator #1
Receiver Setup
9.750 GHz
4.
Local Oscillator #2
Receiver Setup
10.600 GHz
5.
Crossover
Receiver Setup
11.700 GHz
6.
Polarization
Receiver Setup
H (Horizontal)
7.
FEC Rate
Receiver Setup
7/8
8.
Symbol Rate
Receiver Setup
28.3465 MSymbols/s
9.
Network ID
Receiver Setup
1
10.
Lock Level
User Setup
0
11.
Bouquet ID
User Setup
0
12.
TV Audio
User Setup
Left + Right
13.
Baud Rate
User Setup
9600
14.
Aspect Ratio
User Setup
Normal
15.
Local Time
User Setup
12:00 AM
16.
IR Remote
User Setup
Enabled
17.
Date Format
User Setup
US
18.
Video Standard
User Setup
AUTO
19.
Subtitles Language
User Setup
OFF
20.
Password
User Setup
1 2 3 4
21.
Search Mode
Search Setup
OFF
22.
Search Type
Search Setup
Frequency
23.
Lower Range
Search Setup
950 MHz
24.
Upper Range
Search Setup
2150 MHz
25.
IQ Select
Search Setup
Automatic
26.
UHF Channel Setting
38
WARNING!
Saved settings are automatically restored when the receiver is
restarted after AC power is switched off or interrupted. Upon restarting, the
receiver defaults to the last virtual channel displayed for more than 20 sec-
onds after exiting from menus (see also
}
About saving changes in the
Installation and Operation Guide).
Summary of Contents for PowerVu D9234