RTC
®
5 PC Interface Board
Rev. 1.9 e
9 Programming Peripheral Interfaces
212
innovators for industry
Regular (Periodic) External List Starts
Note
• This functionality requires a firmware file in
version 507 or higher (see
) and a
DSP program file in version 511 or higher (see
Via
(bit #10), equidistant external list starts can be
created that are independent of the time point of the
start trigger as long as they occur within the specified
track delay. This strongly periodic list processing is –
independently of a list’s actual duration of execution
and the exact time point of the external list start –
exactly synchronized to the RTC
®
5’s 10
µ
s clock.
If desired, set bit #10 = 1 (
Mode|Bit#10
) to configure
the internal encoder-counter’s processing so that the
track delay of an external list start will
not
be counted
only beginning with the time point of the triggering
external start signal or
command
(bit #10 = 0) but already beginning with the most
recently executed external list start (also executed via
an external start signal or
command) – see
For activation of this mode, an external list start must
have successfully occurred (only one-time) in mode
bit #10=0 (
Mode &
~
Bit#10
). Each subsequent
external list start must be requested within the spec-
ified track delay.
Example
(in PASCAL) of a typical command sequence
(without use of an external start signal):
set_control_mode(Mode &
~
Bit#10);
// (one-time) reset (disable) bit #10 (initialization)
set_start_list_pos(ListNo, Pos);
// open some list
// afterward: some commands
simulate_ext_start(Delay,EncoderNo);
// first time start in mode bit #10 = 0, otherwise in
// mode bit #10 = 1
set_control_mode_list(Mode|Bit#10);
// set bit #10 = 1
// afterward: further commands
set_end_of_list;
// close the list
execute_list_pos(ListNo,Pos);
// (one-time) start the list
If the first start is to be triggered externally (e.g. via
/START or via
) rather than via
command, but all subsequent
starts triggered via
, then
in the above example must
be called before
As of Version DLL 528, OUT 530, after setting
bit#1 = 1, the external start
queue’s entries get explicitly cancelled upon an
external list stop (thereby, external starts can be
permanently stopped via an external list stop).
For older versions and for
bit #1 = 0 (default setting) – after an otherwise infi-
nitely repetitive series has been stopped (e.g. via
, bit #0 = 0) – you should deac-
tivate the track delay and cancel the queue of not-
yet-executed external list starts via
Delay
= 0). Otherwise, the next
“equidistant“ external start won’t have the correct
Bit #10 = 1:
Bit #10 = 0:
1
1
2
2
1
2
Start
Execution
time
Start
Start
Execution
time
Execution
time
Start
Start
simulate_ext_start
/START, /START2 or /Slave-START
Track delay
Start
Execution
time
Track delay
Start
Execution
time
Track delay
Track delay
Track delay
Time
Time
59