8 Advanced Functions for Scan Head and Laser Control
191
innovators for industry
• Monitoring of a rectangular area is also possible
for Rotation-Fly applications, but monitoring of
rotation angle areas isn’t possible.
8.7.10 Tracking Error Compensation
of Encoder Values for
Processing-on-the-fly Applica-
tions
Tracking errors of a scan system’s galvanometer
scanners can result in a certain amount of positioning
inaccuracy, particularly for Processing-on-the-fly
applications with variable encoder speeds. Accord-
ingly, you can activate tracking error compensation
via
for applications requiring
maximum precision.