10 Commands And Functions
495
innovators for industry
Comments
• For aborting a measurement session via
set_trigger
(
Period
= 0) or
Period
= 0), the values of
Signal1
and
Signal2
will be irrelevant as long
as they’re in the permitted value range.
• If you abort a measurement session with
set_trigger
(
Period
= 0) or
Period
= 0), then previously recorded measurement values will
not
be
lost and the measurement pointer will halt at its most recent value. This allows subse-
quent querying via
of the number of successful data entries. In
contrast, if a measurement session is newly started with
set_trigger
and
Period
> 0 or
Period
> 0), the measurement pointer will be reset and the measure-
ments obtained thus far will be overwritten. It is not possible to resume an explicitly or
automatically halted measurement session.
• The type of scan system being used determines which status signals will be generated
and returned via the status channels. Specific information can be found in your scan
system’s operating manual. The
command can be used with
i
DRIVE
®
scan systems (intelli
SCAN
®
, intelli
SCAN
de
®
, intelli
DRILL
®
, intelli
cube
®
,
intelli
WELD
®
, vario
SCAN
de
) to specify which information should be returned via the
status channels.
• If the scan system has only one status channel, then only the X measurement signal will
contain meaningful data.
• With 3D scan systems, the output and status values of the Z axis are transmitted over
the scan head connector’s channel to which the Z axis is attached (if correspondingly
configured via
Example: If the Z axis is attached to the secondary scan head connector’s X channel
(
( [1 or 2], 0 )), then its status signal can be queried via StatusBX
(
Signal1/2
= 4).
• The cartesian control values
Sample<X..Z>
(
Signal1/2
= 7…9) take into account any
wobbel and Processing-on-the-fly corrections, but not image field corrections or coor-
dinate transformations. The RTC
®
5 calculates the “transformed” control values
Sample<AX..BZ>_Trans
(
Signal1/2
= 25…30) from the cartesian control values
Sample<X..Z>
while taking into account any coordinate transformations defined via
or
(or via the corresponding list
commands) and any Z coordinate offset defined via
or any focal length offset defined via
®
5
calculates the “corrected“ control values
Sample<AX..BZ>_Corr
(
Signal1/2
= 10…15)
from the transformed control values
Sample<X..Z>_Trans
while taking into account
any loaded correction table. The effective output values
Sample<AX..BY>_Out
(
Signal1/2
= 20…23) transmitted by the RTC
®
5 to the scan system additionally take
into account any scanner offset and gain compensations for automatic self-calibration
of the scan system (if activated via
, also see
).
• The signals 12 and 15 as well as 27 and 30 are identical, each:
SampleAZ_Corr = SampleBZ_Corr and SampleAZ_Trans = SampleBZ_Trans
.
• The status signals
Status<…>
lag the control signals
Sample<…>
by a few clock cycles.
Delayed Short
List Command
set_trigger