RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
313
innovators for industry
Comments
• While the command is executed, the set position of the scanners is not changed. The
next list command will be executed when the programmed time interval
Period
has
passed.
• Wobbel mode (see
) will be retained, but will be ignored.
• Any softstarts that were defined will not be executed.
RTC
®
4
RTC
®
5 new command
Version info
• Available beginning with version DLL 515, OUT 514, RBF 512
• Changed with version DLL 530, OUT 531, RBF 522: changed functionality for
2
31
Period
(2
32
–1).
References
,
Ctrl Command laser_signal_off
Function
turns off the “laser active” laser control signals immediately
Call
laser_signal_off()
Comments
• This command is intended for direct laser control in combination with the command
(see below).
•
return code
:
RTC5_BUSY
) if the board’s
BUSY status is currently set, i.e. if a list is executing at the moment or if a list has been
halted via
. In contrast, the command is executed when a list has been
paused via
PAUSED status set) or when the board’s INTERNAL-BUSY status is
currently set.
RTC
®
4
RTC
®
5 unchanged
References
Normal
List Command
laser_signal_off_list
Function
same as
(see above), but a list command
Call
laser_signal_off_list()
RTC
®
4
RTC
®
5 unchanged
Variable
List Command
laser_on_pulses_list