RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
473
innovators for industry
Ctrl Command set_rtc4_mode
Function
sets RTC
®
4 compatibility mode as the current DLL operation mode
Call
set_rtc4_mode()
Comments
• RTC
®
4 compatibility mode is an optional operation mode of the DLL. It has been made
available so that user programs written for the RTC
®
4 can also be processed by the
RTC
®
5 (to a large extent) without needing to modify the programming code. However,
a prerequisite here is that the program can only contain RTC
®
4 commands that also
exist with unchanged functionality as RTC
®
5 commands. This user manual’s list of
commands, when applicable, notes such changes in the “RTC
®
4
RTC
®
5” section.
• RTC
®
5 mode is pre-defined as the default DLL operation mode and can also be specified
• The current DLL operation mode can be queried via
.
• The
set_rtc4_mode
is also available without explicit access rights to a particular board.
•
set_rtc4_mode
is not available as a multi-board command.
• This command’s scope is not board-specific, but rather global to the DLL and all RTC
®
5
boards to which the application has access rights.
• The board-specific error variables
LastError
and
AccError
(see
) are neither generated nor altered by
set_rtc4_mode
.
RTC
®
4
RTC
®
5 new command
References
Ctrl Command set_rtc5_mode
Function
sets RTC
®
5 mode as the current DLL operation mode (default setting)
Call
set_rtc5_mode()
Comments
•
sets the DLL operation mode to RTC
®
4 compatibility mode.
• The current DLL operation mode can be queried via
.
• The
set_rtc5_mode
command is also available without explicit access rights to a partic-
ular RTC
®
5 board.
•
set_rtc5_mode
is not available as a multi-board command.
• This command’s scope is not board-specific, but rather global to the DLL and all RTC
®
5
boards to which the application has access rights.
• The board-specific error variables
LastError
and
AccError
(see
) are neither generated nor altered by
set_rtc5_mode
.
RTC
®
4
RTC
®
5 new command
References