RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
369
innovators for industry
Normal
List Command
micro_vector_rel_3d
Function
moves the output point (of the laser focus) via a hard jump (without microvectorization)
directly from the current position to the specified position (relative coordinate values)
within a three-dimensional process volume.
Restriction
If the 3D option is not enabled or no 3D correction table has been assigned (see
), then the command will have the same effect as
Call
micro_vector_rel_3d( dX, dY, dZ, LasOn, LasOff )
Parameters
dX,dY,dZ
relative coordinates of the micro vector end point in
bits
as signed 32-bit
values; allowed range:
• for
X
and
Y
: [–8388608 … 8388607] (out-of-range values will be edge-
clipped). The complete value range [–8388608 … 8388607] is only usable
as a virtual image field e.g. for (enabled) Processing-on-the-fly applica-
tions. The current coordinates will be clipped to [–524288 … 524287] (real
image field size) during runtime directly prior to use of the correction table.
• for
Z
: [–32768 … 32767] (out-of-range values will be edge-clipped).
LasOn,
LasOff
LaserOn delay and LaserOff delay (see
Comments
• The coordinates for the vector’s end point are to be supplied as relative coordinates
with respect to the current position. Otherwise, the command is identical to
(see the comments there).
• The microvector always executes as a hard jump.
RTC
®
4
RTC
®
5 new command
RTC
®
4 compatibility mode: see
Version info
Available with version DLL 536, OUT 536
References