RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
382
innovators for industry
Version info
Available beginning with version DLL 536, OUT 536
References
Ctrl Command pause_list
Function
pauses execution of the list and disables the “laser active” laser control signals.
Call
pause_list()
Comments
•
pause_list
is synonymous with the previous command
confused with
. Therefore, it is preferable to use
pause_list
.
• If
pause_list
is called during execution of a list, the command causes the “laser active”
laser control signals to be disabled (then the laser output ports are in the high imped-
ance tristate mode) and keeps the scan system in the most recently defined state – even
if in the middle of microvectoring. The PAUSED status (queryable via
) is set,
but the BUSY status is left unchanged. Continuation via
or via an external start will be suppressed. However,
or
an external list stop is possible.
or an external list stop will
end suppression of the list start.
• If processing of a list should be continued, then the command
must
be
used. After the successful
command, the scan system resumes the planned
movements (of the current command) and the “laser active” laser control signals are
reenabled (the laser is started with the standard laser parameters, i.e. without any soft-
start or similar parameters that might have been defined prior to
pause_list
). The
PAUSED status is then reset (here too, BUSY remains unchanged).
• If, during calling of the
pause_list
command, no list is currently executing (BUSY status
not set) or a list has already been halted via
pause_list
or
(PAUSED status set),
then the
pause_list
command will be ignored (
return code
RTC5_BUSY
;
the laser is then already off).
RTC
®
4
RTC
®
5 new command
References
,
Ctrl Command quit_loop
Function
stops the repeating automatic list change started with
Call
quit_loop()
Comments
• Before list execution is stopped, the current list will fully execute until the next
• If no
command was previously issued, then
quit_loop
will have no effect.
RTC
®
4
RTC
®
5 unchanged
References
Undelayed
Short List
Command
range_checking
Function
defines an emergency action if a galvanometer exceeds its position limit.
Variable
List Command
park_return