10 Commands And Functions
413
innovators for industry
RTC
®
4
RTC
®
5 In contrast to the RTC
®
4, bit#8 cannot not be used to lock or unlock the upper 8 bits of
the 16-bit digital output port for I/O commands. The RTC
®
5 automatically reserves (locks)
these bits for vario
SCAN
FLEX
control via
. It’s not possible to explicitly release
these bits (release automatically occurs via
).
Otherwise: unchanged functionality for the bits that are also used on the RTC
®
4
Version info
Last change (DLL 528, OUT 530): bit#1
References
,
,
Normal
List Command
set_control_mode_list
Function
similar to
(see above), but a list command
Call
set_control_mode_list( Mode )
Parameter
Mode
(as an unsigned 32-bit value)
Comments
• The counter for external list starts is
not
reset by this command.
RTC
®
4
RTC
®
5 unchanged functionality for the bits that are also used on the RTC
®
4
Version info
Last change (DLL 528, OUT 530): bit#1
References
Ctrl Command set_default_pixel
Function
defines the pulse length default value for the default pixel that terminates pixel output
mode.
Call
set_default_pixel( PulseLength )
Parameters
PulseLength
default pixel pulse length (as an unsigned 32-bit value).
1 bit equals 1/64
µ
s.
Allowed range: [0 … (2
32
–
1)]
Comments
• In pixel output mode, the pixel pulse length at the end of an image line (at the begin-
ning of the default pixel) will get set to the specified default value (see
• When the RTC
®
5 is initialized (via
), the pulse length default value
is set to 0.
RTC
®
4
RTC
®
5 new command
References
Ctrl Command set_control_mode