7
- 139
7
6
x
One main circuit board can control 4 groups (indoor unit groups 0
– 3).
x
Set to “disable” if the indoor unit group does not exist. Set to
“enable” if the indoor unit group exists.
Indoor Unit Enabling Switches
OFF
1 2 3 4
Address switch
1 2 3 4 5 6
Central control
address
- - - - - -
O
- - - - -
-
O
- - - -
O
O
- - - -
1
2
3
4
- -
O
- - -
5
O
-
O
- - -
6
-
O
O
- - -
7
O
O
O
- - -
8
- - -
O
- -
9
O
- -
O
- -
10
-
O
-
O
- -
11
O
O
-
O
- -
12
- -
O
O
- -
13
O
-
O
O
- -
14
-
O
O
O
- -
15
O
O
O
O
- -
16
- - - -
O
-
17
O
- - -
O
-
18
-
O
- -
O
-
19
O
O
- -
O
-
20
- -
O
-
O
-
21
O
-
O
-
O
-
22
-
O
O
-
O
-
23
O
O
O
-
O
-
24
- - -
O
O
-
25
O
- -
O
O
-
26
-
O
-
O
O
-
27
O
O
-
O
O
-
28
- -
O
O
O
-
29
O
-
O
O
O
-
30
-
O
O
O
O
-
31
O
O
O
O
O
-
32
- - - - -
O
33
O
- - - -
O
34
-
O
- - -
O
35
O
O
- - -
O
36
- -
O
- -
O
37
O
-
O
- -
O
38
-
O
O
- -
O
39
O
O
O
- -
O
40
- - -
O
-
O
41
O
- -
O
-
O
42
-
O
-
O
-
O
43
O
O
-
O
-
O
44
- -
O
O
-
O
45
O
-
O
O
-
O
46
-
O
O
O
-
O
47
O
O
O
O
-
O
48
- - - -
O
O
49
O
- - -
O
O
50
-
O
- -
O
O
51
O
O
- -
O
O
52
- -
O
-
O
O
53
O
-
O
-
O
O
54
-
O
O
-
O
O
55
O
O
O
-
O
O
56
- - -
O
O
O
57
O
- -
O
O
O
58
-
O
-
O
O
O
59
O
O
-
O
O
O
60
- -
O
O
O
O
61
O
-
O
O
O
O
62
-
O
O
O
O
O
63
O
O
O
O
O
O
64
Address Switches
1 2 3 4 5 6
OFF
OFF
1 2 3 4 5 6 7
6
-
-
-
-
O
O
O
O
R/C prohibit
R/C prohibit
R/C prohibit
Fan speed
Fan speed
Air direction
7
-
-
O
O
-
-
O
O
8
-
O
-
-
O
-
O
Option 1
Fan speed
Air direction
Filter sign
Air direction
Filter sign
Filter sign
Option 2
Setting Switches
O : ON
- : OFF
Not used (Be sure to set to OFF.)
Not used (Be sure to set to OFF.)
OFF Communicate as a “main” central control device.
ON
Communicate as a “sub” central control device.
x
If there are no central control devices other than this
interface, set to “main” (ON).
x
To set this interface as the main, set only node 0 to
“main” (ON).
x
If using in combination with an communication adapter,
AMY adapter, intelligent controller, or
system
controller, set to “sub” (OFF).
x
If using in combination with an ON/OFF central
controller, set the ON/OFF central controller as the
main if the ON/OFF central controller’s
remote-controller prohibit function is to be used. If this
interface’s remote-controller prohibit function is to be
used, set this interface as the main.
OFF Central/individual setting is according to the central
control device (normal setting).
ON
Central/individual setting is always set to “individual.”
OFF
Indoor unit group 3 is disabled.
ON
Indoor unit group 3 is enabled.
OFF
Indoor unit group 2 is disabled.
ON
Indoor unit group 2 is enabled.
OFF
Indoor unit group 1 is disabled.
ON
Indoor unit group 1 is enabled.
OFF
Indoor unit group 0 is disabled.
ON
Indoor unit group 0 is enabled.
OFF Control temperature is used for the room temperature
(normal setting).
ON Inlet temperature is used for the room temperature.
O
: ON –: OFF R/C: Remote Controller
Mini ECO-i System
Remote Control Functions
9. LonWorks Interface Product Manual
(SHA-LN16UG(B))
06-408 Mini_ECOi_SM7 11/10/06 7:24 PM Page 139