7
- 72
Mini ECO-i System
Remote Control Functions
7
6. Intelligent Controller
(SHA-KT256BG)
6 Using the System
↓
Main
Sub
6
6
10
10
WEB
settings
Note 17
↓
Main
Sub
6
6
11
1111
User settings
Note 17
↓
Main
Sub
4
4
2
2
Cut-off/Data backup
(1) Manual cut-off
Note 6
(2) Data backup
Note 13
(3) Restore
Note 13 and 16
↓
END
Note 1
Settings are necessary when you would like to monitor operation accumulated time only and
distribution ratio is not needed.
Note 2
Settings are necessar
y only when air-conditioners include a 3-W
a
y type unit.
Note 3
Make settings even when no distribution is made, if you would like to control units as a bundle of
the group of tenants.
Note 4
Settings are necessary only when the indoor unit has a local adapter (SHA-KL4UGB) and is set at
almighty
.
Note 5
Settings are necessar
y only f
or the indoor unit set at almighty
.
Note 6
Immediately bef
ore deliv
er
y,
e
xecute
“Clear accum.data”
to clear total data tak
en dur
ing test r
uns
.
When clear
ing the test r
un data after stor
ing it, mak
e
“Cut-off
” (
Main
Sub
4
4
2
2
) manually
.
Note 7
Make the settings when you would like to operate the unit by optional grouping.
Note 8
When using the unit along with the system controller or ON/OFF-controller
, the controller-side
control classification needs to be taken into consideration.
The system controller or ON/OFF-controller-side zone varies as varying central addresses from the
Intelligent Controller
.
Note 9
Settings are necessary only for local adapters (SHA-KL4UGB).
Note 10
Settings are unnecessary for the simple distribution as they will be taken into consideration in
calculation only for the loaded distribution.
Note 1
1
Always set the mode at “NO (Normal)”.
Note 12
Do not make any initialization imprudently as it may cause missing of all the set and cut-off data.
Note 13
The system w
o
rks only with the bac
kup PC card inser
ted, which is separ
ately a
v
ailab
le
.
Note 14
Always manually make the cut-off processing in advance to vary the method of distribution.
Note 15
Although the touch panel is adjusted bef
ore f
a
ctor
y shipment, calibr
ate de
viations if an
y.
Note 16
Do not restore any data imprudently as it may return them to their backed-up status.
Note 17
Settings are necessary when you would like to control/monitor the unit via network.
Air conditioner
operation only
Displaying
distribution ratios
(simple distribution)
Displaying distribu-
tion ratios (loaded
distribution)
H
H
L
L
L
L
L
L
Main
Sub
1
1
5
5
L
L
L
L
L
L
6 Using the System
6.3.2 Setting the date, cut-off date, and distribution ratio calculation
method
Use this screen to set the current date and time
, and mak
e settings related to time
.
These settings are needed f
or prog
ram timers and distr
ib
ution ratio calculation,
so be sure to
make them bef
ore star
ting operation of the system
.
Procedure
Select 5.Initial settings in the main men
u and 1.Date/Distr
ib
. in the sub menu, then proceed as
fo
llo
w
s
.
q
Set the current date and time
.
Under
“(1) Current time”, select the current y
ear
, month, da
y, hour
, minute
, and second from
the drop-do
wn lists(
M
).
The da
y of the week is sho
wn automatically
.
Press the Set button to set the settings.
w
Set the monthly cut-off da
y.
Under
“(2) Cut-off da
y”, select a n
umber from
1 to 28 or End (to select the last da
y of the
month) from the drop-do
wn list(
M
).
q
w
e
r t
1.Status/Control
2.T
otal data/Cut-off
3.Distr
ib
. r
atio
4.Maintenance/T
est Run
5.Initial settings
6.A
uxiliar
y settings
1.Date/Distr
ib
.
2.CNTR/Unit/T
en.
No
.
3.T
en.
name/Distr
ib
. Gr
.
4.Clear accum.
data
Main
Sub
1
1
5
5
06-408 Mini_ECOi_SM7 11/10/06 7:24 PM Page 72