Mini ECO-i System
Remote Control Functions
7
6. Intelligent Controller
(SHA-KT256BG)
This section explains some of the terms used in this manual.
IIIII
Adaptor ad
dress (No.
0 set on Intellig
ent Contr
oller
, No.
1 to 7 set on comm
unication
adaptor
s
)
An adaptor address is the address assigned to an optional comm
unication adaptor
.
IIIII
Link system ad
dress (No.
1 to 2,
fixed)
A link system is a collection of indoor units and outdoor units connected to a single indoor/
outdoor control wire. Up to two link systems each can be connected to the Intelligent Controller
and to an optional comm
unication adaptor
.
IIIII
Outdoor unit system ad
dress (No.
1 to 30 f
or eac
h link system,
set on outdoor unit side)
An outdoor unit system is collection consisting of one outdoor unit and the indoor units
connected to that outdoor unit.
A single link system can contain up to 30 outdoor systems
.
IIIII
Indoor unit ad
dress
Up to 64 indoor units can be connected in one link system.
The Intelligent Controller system suppor
ts up to two link systems connected to the Intelligent
Controller only (128 indoor units), or four link systems (256 indoor units) when an optional
comm
unication adaptor is connected.
Indoor unit addresses
, centr
al control addresses
, and unit names are applied to indoor units
.
•
Indoor unit address
(No
.1~/f
or each outdoor unit system, set on indoor unit side)
An indoor unit address is a unique number within an outdoor unit system.
These n
umbers are assigned to each indoor unit, including units subject to g
roup control.
These n
umbers are the smallest unit of totals calculation and distr
ib
ution calculation.
•
Central contr
ol ad
dress
(No
.1 to 64 f
or each link system, set on Intelligent Controller and
other centr
al control equipment)
A centr
al control address is a unique number within a link system.
It is shared with other
centr
al control equipment (system controllers
, m
ulti controllers
, etc.)
This is the same address used in g
roup control.
•
Unit name
(set on Intelligent Controller)
This is the same name used in group control.
It is the smallest unit of oper
ation, monitor
ing, and timer oper
ations
.
IIIII
Distribution group number (No. 1 to 8, set on Intelligent Controller)
A distr
ib
ution g
roup is made up of one or more tenants
.The total of the distr
ib
ution r
atios in the
g
roup is 100%.
The Intelligent Controller system suppor
ts up to 8 distr
ib
ution g
roups
. GHP
, P
A
C
,
and HO
T units cannot be mix
ed in a single distr
ib
ution g
roup
.
IIIII
T
enant number (No.
1 to 256 set on Intellig
ent Contr
oller)
A tenant is a collection that is the object of distr
ib
ution calculations (or oper
ation and monitor
ing).
It is made up of one or more indoor units
.The system as a whole suppor
ts up to 256 tenants
.
IIIII
Zone number (No. 1 to 128, set on Intelligent Controller)
A z
one is unrelated to distr
ib
ution.
It is a r
ange f
or perf
or
ming all-unit oper
ation, monitor
ing, and
timer oper
ation.
GHP
, P
A
C
, and HO
T units can be mix
ed in a z
one
.The system as a whole
suppor
ts up to 128 z
ones
.
11 TERMS
I
P
o
w
e
ring the system off
Always use the following procedure to power the Intelligent Controller off.
T
ouch the P
o
w
er off b
utton in the
“Other settings”
screen (
Main
Sub
6
6
9
9
).
T
ouch the OK b
utton in the message bo
x which appears to ask if y
ou w
ant to e
xit the prog
ram.
W
ait until a message appears to inf
or
m y
ou that
“It is no
w saf
e to tur
n off the Intelligent Controller
.”
(
∗
)
and then po
w
er the system off
.
(*Se
v
e
ral min
utes ma
y pass bef
ore this message appears
.)
I
Air conditioner limitations
Some types of air conditioners are limited in the settings which the
y suppor
t.
F
or e
xample
, cooling-only air conditions cannot be set to heating.
Floor-type models typically suppor
t only high f
an speeds
.
Ceiling mounted models do not ha
v
e
flaps
, and theref
ore cannot change the f
an direction.
Y
ou should be a
w
are of the limitations of the air conditioner models in y
our system.
F
or more inf
or
mation, contact y
our dealer or ser
vice pro
vider
.
I
Standby power (for simple distribution)
The Intelligent Controller performs distribution calculations on the basis of indoor unit operating time.
Theref
ore it does not count po
w
er consumed while under are stopped (on standb
y).
F
or e
xample
, if no units are oper
ated o
v
er the course of a month, no standb
y po
w
er consumption is
distr
ib
uted to an
y tenant.
Ho
w
e
v
er if a unit is oper
ated f
or e
v
en one minute
, then all of the standb
y po
w
e
r
consumption is distributed to the corresponding tenant.
For loaded distribution, distribution is made with standing-by power added.
I
W Multi GHP outdoor unit data is displayed as “Reference unit”.
Because the reference unit changes depending on operating conditions, the data displayed by the
Intelligent Controller also changes.
Outdoor unit data is data such as
“number of operations”
and
“oper
ating time”.
I
Only an alar
m code is displa
y
ed in the notification bar and alar
m log displa
y.
The content of an alar
m can v
e
ry f
or diff
erent models
, e
v
en if the alar
m code is the same
. Consult the
documentation of the v
a
rious models to deter
mine the content of the alar
m.
I
Because of data tr
ansmission dela
y, the totals and distr
ib
ution data displa
y
ed b
y the Intelligent Controller
for diff
erent time z
one (regular hours
, out of hours
, special da
ys) ma
y not be counted in a completely
accurate f
ashion.
F
or details
, see
“6.6.3
Time z
one totals and distr
ib
ution”.
I
The Intelligent Controller does not suppor
t pr
inting.
If y
ou need to pr
int totals and distr
ib
ution data, please install the optional PC Card on a PC at y
our
location.
I
Filter cleaning signs and oil exchange signs are updated every 1 minutes.
Operating time totals and distribution data are updated every 18 minutes. Electric heater ON time is
updated once an hour
.
I
Cut off processing f
or the pre
vious da
y is perf
or
med e
v
er
y da
y f
or a f
e
w min
utes after 00:00 a.m.
The
system will not respond to user input during this processing.