The figure below shows a typical operating screen.
Main m
e
nu
Sub m
e
nu
O
p
erate o
n
all
units
Outputs hardcopies
by the printer.
T
im
er
operation m
a
rk
This lights when an ind
oor
unit is set up for tim
er
operation.
R
e
set b
u
tton
Stops the buzzer and resets
the alarm display. (Depen
ds on
th
e ty
pe of alarm
.)
Filter
cleaning sign
T
h
is lights when
a filter
cleaning sign has b
een
issued for an indo
or unit.
D
isplay
s
tenant
nam
e.
Display
s the current date and ti
m
e
.
Scrolls the
colum
ns
displa
y
ing indoor
units.
Scrolls the display
of
tenants.
D
isplay
s unit
nam
e.
Notif
ic
ation column
Display
s alarms, e
rrors, an
d o
the
r
me
ssa
ges
.
Intelligent Controller – 1 – 01 – 08
Indoor address (1-64)
Outdoor address (1-30)
Link number (1,2)
Adapter number (Intelligent Controller, 1-7)
1.Status/Control
2.T
otal data/Cut-off
3.Distr
ib
. r
atio
4.Maintenance/T
est Run
5.Initial settings
6.A
uxiliar
y settings
Filter cleaning signs are issued only as appro
ximate guides
.
W
e recommend that filters be cleaned
regular
ly
, e
v
en if no sign has been issued.
6 Using the System
6.3 Initial Settings
The items in the “Initial settings” menu (main menu 5) must be set in order to use the Intelligent
Controller
. Be sure to set these items
.
Before making the settings, read the following and decide what kind of information you want to obtain
from the system.
(1)
Setting central addresses
Central addresses m
ust be set on the
“CNTR/Unit/T
en.No
.”
screen
(
Main
Sub
2
2
5
5
).
Be a
w
are that using them along with the system controller
, ON/OFF-controller and so on, ma
y
affect zone control classification.
(2)
Decide whether or not to use distribution ratios. (See “6.3.2 Setting the date, cut-off date, and
distribution ratio calculation method”.)
Question:
Do y
ou need to displa
y and record
distrib
ution ratios
for each indoor unit and each tenant?
Ye
s
¡
Select “T/S ON+OFF time” or “T/S ON time” as calculation target of power
distribution.
No
¡
Select
“No Distr
ib
.”
as calculation target of po
w
er distr
ib
ution.
If all y
ou need to do is to monitor air conditioning status
, operate the system, and vie
w total data
for oper
ating time and so on, y
ou should select
“No”.
(Inf
or
mation y
ou do not need will not be
displa
y
ed.)
When y
ou select
“No”, the f
ollo
wing displa
ys are disab
led.
Setting
items
:
Distribution group registration in
Main
Sub
3
3
5
5
.
Display items
:
Time zones in
Main
Sub
1
1
2
2
and
Main
Sub
2
2
2
2
.
Menus
:
Main
Sub
1
1
3
3
and
Main
Sub
2
2
3
3
,
Main
Sub
6
6
6
6
,
Main
Sub
6
6
7
7
, and
Main
Sub
6
6
8
8
(3)
If you will be using distribution ratios, decide which
calculation method
to use. (See “6.3.2
Setting the date, cut-off date, and distribution ratio calculation method”.)
Question:
Do y
ou need to consider electr
icity of indoor units?
Ye
s
¡
Select “T/S ON+OFF time” as calculation target of power distribution.
No
¡
Select “T/S ON time” as calculation target of power distribution.
Y
ou can remo
v
e connected units from management b
y
this system.
F
or details
, see
“6.8.2 Setting z
one
numbers and management targets”.
Main
Sub
1
1
5
5
06-408 Mini_ECOi_SM7 11/10/06 7:24 PM Page 70