10 .1
AWRT10RF Wireless Radiant Thermostat -
Troubleshooting
Error Message
Description
Corrective Action
ER:VA DEVICE
Thermostatic Radiator Valve
(TRV) hardware issue .
Remove the ARV10RFM or AVA10M30RF Actuator from the radiator
valve and check to see if the valve plunger is operating
If the plunger is working correctly, try resetting the actuator as
described in Section 8
ER:XSNSR OPEN
External Sensor Open – Not Connected:
Parameter P15 is enabled for external sensor
but no sensor connection is detected .
If no external sensor is used, disable Parameter P15 .
If an external sensor is used, check continuity of the circuit .
Check for wire damage or defective sensor .
ER:XSNSR SHORT
Externa Sensor Short:
Control senses no resistance
across sensor .
Check for wire damage creating sensor lead short circuit .
Compare sensor resistance to the chart supplied below . If the
resistance value is significantly different than predicted by the
chart, replace the sensor .
ER:LLNK RC
Lost Link with Relay Controller
Reset the Relay Controller and AWRT10RF Thermostat .
Repeat pairing procedure .
ER:LLNK VA #
Lost Link with ARV/AVA valve actuators:
# indicates total number of valves
Reset ARV/AVA Actuators and AWRT10RF Thermostat .
Repeat pairing procedure .
ER:LLNK RCV1
Lost Link with Receiver: Configured as RX1
Reset AX10RF Receiver and AWRT10RF Thermostat .
Repeat pairing procedure .
ER:LLNK RCV2
Lost Link with Receiver: Configured as RX2
Reset AX10RF Receiver and AWRT10RF Thermostat .
Repeat pairing procedure .
ER:LLNK ZN #
Lost Link with Thermostat for Zone (1-8)
of this Relay Controller
Reset Thermostat corresponding with the ZN message .
Repeat pairing procedure .
ER:LLNK RC-CO
Lost Link between Relay Controller
and Coordinator/Gateway
Reset Relay Controller . Repeat pairing procedure .
ER:LLNK RC-RCV
Lost Link between Relay Controller
and Receiver (RX1)
Reset Receiver and repeat pairing procedure .
ER:LLNk VA-CO
Lost Link between ARV/AVA Valve
Actuator and Coordinator
Reset ARV/AVA Actuator
ER:LOWBAT VA
Low Battery ARV/AVA Actuator
Replace batteries in the ARV/AVA Actuator .
ER:VA GEAR
Gear Issue with ARV/AVA Valve Actuator
Replace the ARV/AVA Actuator .
ER:VA ADAPT
Issue with adapting ARV/AVA Actuator
and valve combination
Reset ARV/AVA Actuator and Thermostat and repeat the Pairing
procedure .
Error messages are displayed on the alphanumeric text line at the top of the screen . These
messages will alternate with the current status message .
Error Messages