4 .12
• This pairing procedure is only used when direct control of an AX10RF Receiver by the AWRT10RF
Thermostat is desired.
• Each system will support only one AX10RF configured as RX1 and one configured as RX2. These two
configurations can be used together to provide boiler switching and zone valve operation.
JOINING- - - will be displayed with a 10
minute countdown timer and a flashing
network status indicator .
Step 1. On the AWRT10RF Thermostat,
press until PAIR? RCV2 is displayed .
Press SELECT .
Step 2. Open the SALUS Smart Home mobile application and select the drop-down menu from
the upper right side of the screen:
Equipment
Add New Equipment
Scan for Equipment
Step 3. Click the “Scan for equipment” button . The SG888ZB Gateway will flash red as it searches
for devices .
Pairing with AX10RF Receiver for Zone Valve Switching (RX2)
Section 4
AWRT10RF Pairing with
Internet Connection (SG888ZB Gateway)