6 .7
• This pairing procedure is only used when direct control of an AX10RF Receiver by the
AWRT10RF Thermostat is desired.
• Each system will support only one AX10RF configured as RX1 and one configured as RX2.
The following configuration is typical in boiler systems in which there is only one thermostat in the
system such as a single steam heating loop or single forced circulation, hot water loop. For systems
with multiple zones, a zone relay controller such as the SALUS AKL Series is recommended.
Before starting the pairing process, be sure that the AX10RF Receiver is installed as shown in the
installation instructions included with the device .
• The switch on the inside cover must be configured to RX1 .
• The LED backlight on the Auto/Manual switch of the AX10RF Receiver should be flashing red .
• The Auto/Manual switch of the AX10RF Receiver should be in the AUTO position .
• The AWRT10RF Thermostat should be powered up and flashing PAIR? RLAY_CTL .
JOINING- - - will be displayed with a 10
minute countdown timer and a flashing
network status indicator .
Step 2. On the AWRT10RF Thermostat,
press until PAIR? RCV1 is displayed .
Press SELECT .
Step 1. Press and hold the lighted red pairing
button on the AC10RF Coordinator for 5
seconds, until the LED begins to flash .
Pairing with AX10RF Receiver for Boiler Switching (RX1)
Section 6
AWRT10RF Pairing without Internet
Connection (AC10RF Coordinator)