Service Menu, Aux Select
The
Aux Select
menu is used to select the number of analog auxiliary inputs on the keypanel when the panel has been licensed
for OMNEO 3-8.
When a keypanel is not licensed, meaning it only has OMNEO 1 and 2, then the number of analog aux inputs is the maximum
supported by the panel:
•
KP-5032/4016 - Maximum number of Analog Aux = 2, OMNEO 1-2, plus Aux 1-2
•
DKP-4016 - Maximum number of Analog Aux = 1, OMNEO 1-2, plus Aux 1
•
KP-3016- Maximum number of Analog Aux = 0, OMNEO 1-2
•
KP-3016A does not support OMNEO
When the keypanel is licensed for OMNEO 3–8, OMNEO 8 and Aux 1 are multiplexed, meaning you can have one or the
other, but not both. The same rule applies to OMNEO 7 and Aux 2; both are multiplexed and both cannot be used together.
Also, you cannot have Aux 2 without Aux 1.
The options available if OMNEO 3–8 are licensed:
•
Number of Analog Aux = 2, OMNEO 1-6, plus Aux 1-2
•
Number of Analog Aux = 1, OMNEO 1-7, plus Aux 1
•
Number of Analog Aux = 0, OMNEO 1-8
Service Menu, CWW
The
CWW
menu is used to configure the CWW (Call Waiting Window). There are two configuration options; how many calls
can be shown in the CWW and what happens to the highlight when a new call comes in to the keypanel.
Number of Entries
The
Number of Entries
sub-menu is used to define how many calls can be shown in the CWW. The maximum number of
entries is 9, while the minimum is 3 (2 in Unicode).
To
select the number of entries allowed for the CWW
, do the following:
1.
Starting at the Service menu, select
CWW
.
2.
Press the
SEL button
.
Number of Entries and On New Caller appears in the panel display.
3.
Using the arrow buttons, select
Number of Entries
.
4.
Press the
SEL button
.
The Number of CWW Entries scroll list appears.
5.
Using the arrow buttons, select between
3 and 9 entries
.
On New Caller
The
On New Caller
sub-menu is used to configure what action occurs in the CWW when a new call enters the queue.
The options available for this menu are:
Select New Call
When a new call enters the CWW queue, it goes to the top of the list and is then selected.
The highlight moves to this item.
Don’t Select (default)
When a new call enters the CWW queue, it goes to the top of the queue, but the
highlighted item does not change.
Summary of Contents for DKP-4016
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Page 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Page 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...