106 Basic Operation
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248 Rev. 03
GPI Inputs Assignments Group Box
The
GPI Inputs Assignment
group box is used to configure GPI inputs on the keypanel. Inputs can be assigned to activate
intercom keys (including group master keys).
Further configuration can be done to allow GPI Inputs to track the state of the Output. For example, if an output is activated
(and is being tracked by an input), the input is also activated. This feature allows GPIO Outputs to control Talk Key or Key
Group activation.
In addition to tracking, you can also configure the way an Input GPIO Key Group is configured. By default, when a key group
is activated, the keys are forced on until the key group is deactivated. This is referred to as Level Mode. Alternatively, you can
configure the key group to Edge Mode. This option turns on keys in a key group when the group is activated, but allows the
user to turn off individual keys even if the key group is still active.
For a description of the selections available, see “Service Menu, Local GPIO” on page 232.
To
configure the GPI Input Assignments
, do the following:
1.
From the Assign To column drop down menu, select whether the
input is assigned to a talk key or a key group
.
2.
From the Track column drop down menu, select the whether the
input should track the output.
3.
From the Key/Group column drop down menu, select the
key or group
the input is configured to.
4.
From the Key Mode drop down menu, select the
behavior of keys in a group
when they are activated.
GPI Output Assignments Group Box
The
GPI Output Assignments
group box is used to assign Relays 1 and 2 to keys on the keypanel.
To
configure the GPI Output Assignments
, do the following:
>
From the Key/UPG column drop down menu next to the relay you want, select the
key or UPG
you want to assign
the relay.
FIGURE 33.
Panel Options Page – GPI Input Assignments Group Box
FIGURE 34.
Panel Options Page – GPI Output Assignments Group Box
Summary of Contents for DKP-4016
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Page 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Page 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Page 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...