SYSTem Related Commands
SYSTem:BEEPer
[
:IMMediate]
Makes buzzer beep once.
Parameter: <None>
Example: SYST:BEEP:IMM
●This function is Not affected by the state of
SYST:BEEP:STAT.
SYSTem:BEEPer:ERRor
Sets the beeper to sound on an SCPI error.
Parameter: 0 | 1 | ON | OFF
Example: SYST:BEEP:ERR ON
Allows the beeper to sound when an SCPI error occurs.
SYSTem:BEEPer:ERRor?
Returns the beeper error mode.
Return parameter: 0 | 1, 0=OFF, 1=ON
SYSTem:BEEPer:STATe
Turns the buzzer on/off.
Parameter: 0 | 1 | ON | OFF
Example: SYST:BEEP:STAT 0FF
Turns the buzzer off.
●The key sound of front panel is Not affected by the state.
●The command of SYSTem:BEEPer is Not affected by the state.
SYSTem:BEEPer:STATe?
Returns the buzzer state.
Return parameter: 0 | 1, 1=ON, 0=OFF.
SYSTem:BEEPer:COMPare:VOLume
Sets the beeper volume of Compare function.
Parameter: <NR1> (0 ~ 2)
0(small), 1(Medium) , 2(Large)
Example: SYST:BEEP:COMP:VOL 2
Sets the beeper volume to large of Compare function.
SYSTem:BEEPer:COMPare:VOLume?
Returns the beeper volume of Compare function.
Return parameter: SMALL | MEDIUM | LARGE
SYSTem:BEEPer:CONTinuity:VOLume
Sets the beeper volume of Continuity function.
Parameter: <NR1> (0 ~ 3)
Example: SYST:BEEP:CONT:VOL 1
Sets the beeper volume to small of Continuity function.
Summary of Contents for RSDM-9060
Page 1: ...User Manual RSDM 906X series Stock number 1919720 RSDM 9061 1919721 RSDM 9060 EN rspro com...
Page 2: ......
Page 5: ...5 Dimensions 409 Declaration of Conformity 410...
Page 141: ...141 EOM pulse width timing...
Page 160: ...160 rspro com SYSTEM FIRMWARE View System Info 161 Firmware Update 162...
Page 211: ...211 SCREENHOT LOG Capture 212 Save Reading 215...
Page 409: ...409 Dimensions All dimensions are shown in millimeters...
Page 412: ...412 rspro com...