10–20 • Appendix A. Specifications
Synergy 100 Installation Guide (v16.10-S100)
Aux Panel Programming Mode Summary
The following table summarizes all normal, GPI and special diagnostic Aux panel programming
modes for new generation Remote Aux Panels for the S100
Aux Panel Programming Mode Button Assignment
Button/
LED
Normal
Mode
Program Mode
Bus Assignment
Program
Mode
GPI Offset
Program Mode
GPI Status
Power Up
Diagnostics
1 (Black)
Select Xpt 1
Display/modify this panel’s rights
to Aux Bus 1 (Dedicated panels
only) (*6)
Set GPI to group 1
(offset 0) (*1)
GPI 8 Status (ON =
shorted to ground)
Start Walking
LED Test (*3)
2
Select Xpt 2
Display/modify this panel’s rights
to Aux Bus 2 (Dedicated panels
only) (*6)
Set GPI to group 2
(offset 1) (*1)
GPI 7 Status (ON =
shorted to ground)
Start Pushbutton
LED Test (*3)
3
Select Xpt 3
Display/modify this panel’s rights
to Aux Bus 3 (Dedicated panels
only)
Set GPI to group 3
(offset 2) (*1)
GPI 6 Status (ON =
shorted to ground)
Start DUART
Test (*3) (*4)
4
Select Xpt 4
Display/modify this panel’s rights
to Aux Bus 4 (Dedicated panels
only)
Set GPI to group 4
(offset 3) (*1)
GPI 5 Status (ON =
shorted to ground)
Start EEPROM
Test (*3)
5
Select Xpt 5
Display/modify this panel’s rights
to Aux Bus 5 (Dedicated panels
only)
Set GPI to group 5
(offset 4) (*1)
GPI 4 Status (ON =
shorted to ground)
6
Select Xpt 6
Display/modify this panel’s rights
to Aux Bus 6 (Dedicated panels
only)
Set GPI to group 6
(offset 5) (*1)
GPI 3 Status (ON =
shorted to ground)
7
Select Xpt 7
Display/modify this panel’s rights
to Aux Bus 7 (Dedicated panels
only)
Set GPI to group 7
(offset 6) (*1)
GPI 2 Status (ON =
shorted to ground)
8
Select Xpt 8
Display/modify this panel’s rights
to Aux Bus 8 (Dedicated panels
only)
Set GPI to group 8
(offset 7) (*1)
GPI 1 Status (ON =
shorted to ground)
9
Select Xpt 9
Display/modify this panel’s rights
to Aux Bus 9 (Dedicated panels
only)
Switch to GPI
Program Mode –
GPI Status and
LED will start
flashing.
Switch to GPI
Program Mode –
GPI Offset and LED
will stop flashing.
10 (Shift)
Select Xpt 10
Display/modify this panel’s rights
to Aux Bus 10 (Dedicated panels
only)
Xpt 10 to be used
as Shift button for
shifted Xpts when
lit. (*2)
Xpt 10 to be used as
Shift button for
shifted Xpts when
lit. (*2)
LED used in
EEPROM Test
ASSIGN 1
to 10
inclusive
Select Aux Bus
Display/modify this panel’s rights
to the respective 10 Aux Buses
(Assignable Panels only)
MLE PV
Select MLE
Preview
Summary of Contents for Synergy 100
Page 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Page 10: ......
Page 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Page 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Page 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Page 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Page 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Page 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Page 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Page 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Page 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...