Specifications and Reference Data
May 2016
Reference Manual
00809-0100-4530, Rev DD
218
Specifications and Reference Data
A.1.6 Display and configuration
Integral display (option code M1)
The integral digital display can toggle between: level,
distance, volume, internal temperature, interface distance,
interface level, peak amplitudes, interface thickness,
percentage of range, analog current out.
Note
The display cannot be used for configuration purposes.
Remote display
Data can be read from the optional integral display or
remotely using the Rosemount 751 Field Signal Indicator
for 4-20 mA / HART (see
), or the
Rosemount 752 Remote Indicator for F
OUNDATION
Fieldbus
(see
Configuration tools
Rosemount Radar Master (included in the delivery)
Device Descriptor (DD) based systems, e.g. AMS
™
Device
Manager, 475 Field Communicator, and DeltaV
™
Device Type Manager (DTM
™
) based systems (compliant
with version 1.2 of the FDT
®
/DTM specification),
supporting configuration in for instance Yokogawa
Fieldmate/PRM, E+H FieldCare
®
, and PACT
ware
™
Output units
Level, interface and distance: ft, inches, m, cm, or mm
Level rate: ft/s, m/s, in./min, m/h
Volume: ft
3
, inch
3
, US gals, Imp gals, barrels, yd
3
, m
3
, or
liters
Temperature: °F and °C
Output variables
Damping
0-60 s (2 s, default value)
5301 5302 5303 PV, SV,
TV, QV
Level
X
X
X
X
Distance to Level
(Ullage)
X
X
X
X
Level Rate
X
X
X
X
Signal Strength
X
X
X
X
Volume
X
X
X
X
Internal Temperature
X
X
X
X
Interface Level
(X)
(1)
1.
Interface measurement only for fully submerged probe, see
.
X
N/A
X
Interface Distance
(X)
X
N/A
X
Interface Level Rate
(X)
X
N/A
X
Interface Signal
Strength
(X)
X
N/A
X
Upper Layer Thickness
(X)
X
N/A
X
Lower Volume
(X)
X
N/A
X
Upper Volume
(X)
X
N/A
X
Signal Quality
X
X
X
(X)
(2)
2.
Not available as primary variable.
Surface/Noise Margin
X
X
X
(X)
Vapor DC
X
N/A
N/A
(X)
Analog Output
Current
(3)
3.
LCD display variable only. Not available for F
OUNDATION
Fieldbus,
Modbus Signal Output, or for HART units in fixed current mode.
X
X
X
N/A
% of Range
(4)
4.
LCD display variable only. Not available for F
OUNDATION
Fieldbus
Signal Output.
X
X
X
N/A