May 2016
Reference Manual
00809-0100-4530, Rev DD
292
Figure B-1. System Control Drawing for Hazardous Location Installation of Intrinsically Safe FM Approved Apparatus
FM Approved Product
No revisions to this drawing
without prior Factory Mutual
Approval.
A3
ORIGINAL
SIZE
GU-LN
0644
5300
GU-PO
6
P
D
F
9240 030-936
9240
030-936
0644
SYSTEM CONTROL DRAWING
for hazardous location installation of Intrinsically
Safe FM approved apparatus
5
1 / 1
ISSUED BY
APPROVED BY
WEEK
WEEK
PRODUCT CODE
DOC. TYPE
FILE
TITLE
DWG NO.
ISSUE
SHEET
SCALE
1:1
1 ST ANGLE
FINISH, UNLESS
OTHERWISE STATED:
ALL DIMENSIONS ARE IN MILLIMETRES.
The copy
right/ownership of this document is and will remain ours.
The docu
ment must not be used without our authorization or brought
to the knowle
dge of a third party. Contravention will be prosecuted.
Rosemount Tank Radar AB, Sweden
ASSOCIA
TED APP
A
RA
TUS
BARRIER
POWER
SUPPL
Y
HAZARDOUS L
O
CA
TION
NON-HAZARDOUS L
O
CA
TION
ENTITY
CONCEPT
APPROV
AL
T
he Entit
y c
onc
ept allo
ws int
e
rc
onnec
tion of in
trinsically saf
e appar
atus t
o
associat
ed appar
atus
not specifically examined in c
ombination as a syst
em.
T
he appr
o
v
ed v
alues of max.
open cir
cuit
v
oltage (
V
oc or
Vt) and max.
shor
t cir
cuit curr
e
nt (Isc or I
t) and max.
po
w
er (
V
oc x Isc / 4) or (
Vt x I
t / 4),
for the associat
ed appar
atus must be less than or equal t
o
the maximum saf
e input v
oltage (
Vmax),
maximum saf
e input curr
e
nt (Imax),
and maximum saf
e input po
w
er (Pmax) of the intrinsically saf
e
appar
atus
. In addition,
the appr
o
v
ed max.
allo
wable c
onnec
ted capacitanc
e (C
a or C
o) of the associat
ed
appar
atus must be gr
eat
er than the sum of the int
e
rc
onnec
ting cable capacitanc
e and the unpr
ot
ec
ted
int
e
rnal capacitanc
e (Ci) of the intrinsically saf
e appar
atus
, and the the appr
o
v
ed max.
allo
wable
connec
ted induc
tanc
e (La or L
o) of the associat
ed appar
atus must be gr
eat
er than the sum of the
int
e
rc
onnec
ting cable induc
tanc
e and the unpr
ot
ec
ted int
e
rnal induc
tanc
e (Li) of the intrinsically
saf
e appar
atus
.
Not
es:
1.
No r
e
vision t
o
this dr
a
wing without prior F
a
c
tor
y Mutual appr
o
v
al.
2.
A
ssociat
ed appar
atus manufac
tur
er's installation dr
a
wing must be f
ollo
w
ed when
installing this pr
oduc
t.
3.
Dust-Tight seal must be used when installed in Class II and Class III en
vir
onments
.
4.
C
o
ntr
ol equipment c
onnec
ted t
o
the barrier must not use or gener
at
e mor
e than 250
V
rms or
Vdc
.
5.
Resistanc
e betw
een Intrinsically Saf
e
Gr
ound and Ear
th Gr
ound must be less than 1.0 ohm.
6.
Installations should be in acc
or
danc
e with ANSI/ISA-RP12.6 "Installation of Intrinsically Saf
e
S
y
st
ems f
or Hazar
dous L
ocations" and the National Elec
tric C
o
de (ANSI/NFP
A 70).
7.
T
he associat
ed appar
atus must be F
a
c
tor
y Mutual Appr
o
v
ed
.
8.
C
onnec
t supply wir
es t
o
the appr
opriat
e
t
e
rminals as indicat
ed on the t
e
rminal block and in the installation documents
.
ROSEMOUNT 5300 SERIES
Intrins
ic
a
lly
S
af
e
A
pp
aratus
fo
r
u
s
e
in
C
las
s
I,II,
III,
Div
is
io
n
1,
G
roups
A,B
,C,D
,E,F
,G
,
Clas
s
I,
Z
o
n
e
0
,
A
Ex
ia
IIC
T
4,
T
e
m
per
atur
e
C
las
s
T
4
:
M
o
d
e
l
E
n
tit
y
P
aram
et
er
s
A
m
b
ie
n
t
T
e
mp
erat
u
re
Li
mi
ts
4-
20
m
A
/HART
IS
M
od
el
Vm
ax
(U
i)
<=
3
0
V,
Im
ax
(I
i)
<=
13
0
m
A
Pi
<
=
1
W
,
C
i
=
7.26 nF,
Li
= 0 uH
-5
0<
=T
a<
=7
0d
e
g
C
F
iel
dbus
IS
M
o
d
e
l
V
m
a
x
(Ui)
<
=
3
0V,
Im
a
x
(Ii)
<
=
3
0
0
m
A
P
i
<=
1
.3
W
,
C
i
=
0
,
Li
=
0
uH
-5
0<
=T
a<
=6
0d
e
g
C
Fiel
dbus
FI
SCO
IS
M
ode
l
V
m
a
x
(Ui)
<
=
17.5V, Imax(Ii) <= 380 mA
Pi
<
=
5.
32
W
,
Ci
=
0
,
L
i
=
0
u
H
-5
0<
=T
a<
=6
0d
e
g
C
SME-5513
0644
1
ISSUE
CH. ORDER No
WEEK
ISSUE
CH. ORDER No
WEEK
ISSUE
CH. ORDER No
WEEK
ISSUE
CH. ORDER No
WEEK
2
SME-5879
0751
3
SME-7117
1143
4
SME-7469
1242
5
SME-7655
1409
W
ARNING :
To
pr
ev
ent ignition of flammable or c
ombustible atmospher
es
, r
ead ,
understand and adher
e t
o
the
manufac
tur
er's liv
e maint
enanc
e pr
oc
edur
es
.
W
ARNING:
Substitution of c
omponents ma
y impair Intrinsic Saf
e
ty
.
W
ARNING:
P
o
te
ntial Elec
tr
ostatic Char
ging Hazar
d –
T
he enclosur
e is a non-metallic c
onstruc
tion.
T
o
pr
ev
ent
the risk of elec
tr
ostatic spark
ing the plastic sur
fac
e should only be cleaned with a damp cloth.
W
ARNING:
T
he appar
atus enclosur
e c
o
ntains aluminum and is c
onsider
ed t
o
c
onstitut
e a pot
e
ntial risk of
ignition b
y
impac
t or fric
tion.
C
a
re
must be tak
en int
o
acc
ount during installation and use t
o
pr
ev
ent impac
t or fric
tion.
14
03
21 Electronic Master
PRINTED COPIES ARE UNCONTROLLED
Rosemount Propriety