![Rosemount 5300 Series Reference Manual Download Page 180](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396180.webp)
166
Reference Manual
00809-0100-4530, Rev DD
May 2016
7.10
Logging measurement data
By using the Log Device Registers function in the RRM software, you can log Input and
Holding registers over time. It is possible to choose from different pre-defined sets of
registers. This function is useful for verifying that the transmitter works properly.
To log device registers, choose the
Tools > Log Device Registers
option to open the
Log
Registers
window:
Figure 7-14. The Log Registers Function
To start logging:
1.
Select the
Browse
button, select a directory to store the log file, and type a log file
title.
2.
Select the
Select Register
button and choose register type to be logged.
3.
Select the desired registers to be logged. There are three options available:
Standard, Service, and Custom. Standard and Service refer to pre-defined sets of
registers. The Custom option lets you choose the desired range of registers.
4.
Enter the update rate. An update rate of for example 10 seconds means that the
plot will be updated every 10 seconds.
5.
Select the
Start Log
button. The logging will proceed until stopped by clicking the
Stop Log
button.
Start Log
Browse
Select Register
Update rate